摘要
采用热平衡方程式推导出地下柴油发电机房通风量的计算公式,并根据其不同冷却方式的特点,提出了改善机房热环境的措施和方法。
Deduces formulas of ventilating volume in
underground diesel engine generator rooms from thermal balance relationships, presents
measures and ways of improving thermal environment in the room according to the different
characteristics of each cooling mode.
出处
《暖通空调》
北大核心
1999年第4期49-51,共3页
Heating Ventilating & Air Conditioning
关键词
柴油发电机
机房
通风
热平衡
diesel engine generator, machine room,