期刊文献+

F22/P91异种钢接头裂纹原因分析及焊接修复 被引量:2

Analysis on cracking in F22/P91 dissimilar steel joint
下载PDF
导出
摘要 某高压主汽门阀用F22/P91异种钢焊接接头运行时,表面及其内部产生裂纹。文中采用金相显微镜、SEM、显微硬度仪等对焊接裂纹进行检验。结果表明,P91钢及堆焊层强度低、焊接及热处理工艺不合理,是导致接头产生裂纹的主要原因。通过采用合理的焊接和热处理工艺,避免了异种钢接头裂纹的产生,确保了机组的安全可靠运行。 Crack appears in the F22/P91 dissimilar steel joint in High-Pressure Main Steam Valve.It was tested by metallurgical microscope, SEM,and micro hardness tester.The results indicate that the difference of strength between the deposited metal and base metal and the unreasonable welding process and heat treatment process are the main reason caused the crack in the joint.The crack was prevented in dissimilar steel joint by the proper welding process and heat treatment process,which can assure the units to be safely running.
出处 《焊接》 北大核心 2010年第12期14-17,共4页 Welding & Joining
关键词 F22/P91 异种钢接头 裂纹 原因分析 焊接修复 F22/P91 dissimilar steel joint crack reason analysis welding repairing
  • 相关文献

参考文献4

  • 1牛锐锋,孟卫如,赵健仓,王淦刚.P91与10CrMo910异种钢焊接接头特性分析[J].焊接学报,2005,26(8):56-60. 被引量:8
  • 2束国剐.超临界锅炉用T/P91钢的组织性能与工程应用[M].西安:陕西科学技术出版社.2006.
  • 3Effertz P H,Meisel H.Scaling of high temperature steels in high pressure steam after long service[J]. Maschinen Schaden, 1971,55(44): 14-20.
  • 4Rehn L M.Corrosion problems in coal-fired boiler super- heater and reheater tubes:steam-side oxidation and exfolia- tion [R].Review and Results of Laboratory Tests. Palo Alto, California,USA, 1981.

二级参考文献7

共引文献7

同被引文献26

引证文献2

二级引证文献9