摘要 目的了解酸性氧化电位水对消化內镜的消毒作用。方法说明酸性氧化电位水的生成及消毒原理,以及对消化內镜的清洗消毒方法,与戊二醛相比较。结果与戊二醛相比,酸性氧化电位水具有消毒时间相对较短、消毒范围广(包括镜身、钳道、注水/气孔和附件等)、对环境无污染,对人体和内镜均非常安全等优点。结论酸性氧化电位水是较为理想的消化內镜消毒剂,消毒前应把好内镜清洗质量关,还需经常检测酸性氧化电位水的pH值、有效氯浓度和氧化还原电位差,确保消毒效果。
出处 《中国消毒学杂志》 CAS 2011年第2期248-249,共2页 Chinese Journal of Disinfection
  • 相关文献

参考文献5

  • 1Nelson DB, Bosco JJ, Curtis WD, et al. Technology status evaluation; sheathed endoscopes: November 1998, From the ASGE, A- merican society for Gastrointestinal Endoscopy [ J ]. Gastrointest Endosc, 1999,49(6) :862.
  • 2Nelson D. Newer technologies for endoscope disinfection: electrolyzed acid water and disposable component endoscope systems[ J]. Gastmintest Endosc Clin N Am, 2000,10 (2) :319.
  • 3CronmiUer JR, Nelson DK, Salman G,et al. Antimicrobial efficacy of endoscopic disinfection procedures: a controlled, multifacto- rial investigation [J]. Gastrintest Endosc. 1999,50(2) :152.
  • 4何少璋,周惠联,杨国标.强氧化高电位酸化水在内窥镜消毒中的作用评价[J].现代医院,2006,6(1):28-29. 被引量:5
  • 5钟捷,孙波,许斌,季育华,江石湖.酸化电解水消毒法对内镜及附件消毒效果的评价[J].世界华人消化杂志,2003,11(3):364-366. 被引量:13

二级参考文献11

  • 1薛广波.实用消毒学[M].北京:人民军医出版社,1999.403-404.
  • 2杨明华 易滨.现代医院消毒学[M].北京:人民军医出版社,2002.173.
  • 3朱建新.消毒内镜护士手册[M].南京:江苏科学出版社,1999.20.
  • 4Rutala WA, Weber DJ. Disinfection of endoscopes:review of new chemical sterilants used for high level disinfection. Infect Control Hosp Epedemiol 1999,20:69-76
  • 5Nelson DB, Bosco JJ, Curtis WD, Faigel DO, Kelsey PB, Ieung JW, Mills MR, Smith P, Tarnasky PR, VanDam J, Wassef UY. Technology status evaluation, sheathed endoscopes: November 1998,From the ASGE,American society for Gastrointestinal Endoscopy. Gastrointest Endosc 1999,49:862-864
  • 6Raynard JC, Daisy O, Anthony JD Jr. GI endoscopic reprocessing practices in the United States. Gastrointest Endosc 1996,43:540-545
  • 7Tsuji S, Kawano S, Oshita M, Ohmae A, Shinomura Y, Miyazaki Y, Hivaoka S, Natsuzawn Y, Kamadu T, Hori M, Maeda T. Endoscopic disinfection using acidic electrolytic water. Endoscopy 1999,31:528-535
  • 8Cronmiller JR, Nelson DK, Salman G, Jackson DK, Dean RS, Hsu JJ, Kim CH. Antimicrobial efficacy of endoscopic disinfection procedures: a controlled, multifactorial investigation.Gastrintest Endosc 1999,50:152-158
  • 9Axon A, Kruse A, Urgell R, Struelens M, Petersen C, Spencer K, Rey JF, Reid A, Doherty B, Doherty B, Stief M, Cramer J. Europe society of gastrointestinal endoscopy guidelines for the reprocessing of accessories in digestive endoscopy. Endoscopy 1996,28:534-535
  • 10Wilkinson M, Simmons N, Bramble M, Leicester R, D'Silva J, Boys R, Gray R. Report of the working party of the endoscopy committee of the British Society of Gastroenterology on the resue of endoscopic accessories. Gut 1998,42:304-306

共引文献14

同被引文献90

引证文献9

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部