期刊文献+

SAS和气流粉碎工艺制备的两种微粉化布地奈德及其气雾剂质量的比较研究 被引量:2

Comparative study on the quality of micronized budesonide and its aerosol by SAS and air jet pulverization
下载PDF
导出
摘要 目的对超临界流体抗溶剂(SAS)和气流粉碎工艺制备的微粉化布地奈德及其气雾剂的质量进行比较研究。方法分别采用扫描电子显微镜和DSC法对粉体进行分析;激光粒度测定仪对气雾剂的粒径进行分析;HPLC法测定气雾剂的含量、每揿主药含量和雾粒分布。结果 SAS法比气流粉碎工艺制备的微粉粒度更小,分布更均匀,对应的气雾剂每揿主药含量差异小、雾粒药物量更高。结论 SAS法在吸入制剂的应用中具有更好的优越性和更广阔的前景。 Objective The quality of micronized budesonide and its aerosol made by supercritical anti-solvent(SAS) and air jet pulverization were studied comparatively in this article.Methods The power were analyzed by scanning electron microscopy and DSC.The particle size of aerosol was determined by the laser particle size analyzer.The particle size distribution,content of active ingredient and content of budesonide aerosol were measured by HPLC.Results The particle size of budesonide prepared by SAS technology was smaller and uniformly distributed than that prepared by air jet pulverization,and the particle size distribution was more uniformly and content of active ingredient was more of budesonide aerosols prepared by SAS technology.Conclusion SAS technology has more advantage and more extensive application prospect in inhalation preparation.
作者 牛桂云
出处 《齐鲁药事》 2011年第2期69-71,共3页 qilu pharmaceutical affairs
关键词 超临界流体抗溶剂法 气流粉碎法 布地奈德 微粉化 气雾剂 Supercritical anti-solvent Air jet pulverization Budesonide Micronization Aerosol
  • 相关文献

参考文献4

二级参考文献55

共引文献15

同被引文献9

  • 1陈桂良,侯惠民.吸入用气雾剂雾粒测定方法的评价[J].中国医药工业杂志,2007,38(3):194-199. 被引量:24
  • 2Burgess DJ, Dully E, Etzler F, et al. Particle size analysis: AAPS workshop report, cosponsored by the Food and DrugAdministration and the United States Pharmacopeia [J]. AAPSJ, 2004, 6 (3): 23-24.
  • 3Dunbar C, Mitchell J. Analysis of cascade impactor mass distributions [J]. JAerosol Med, 2005, 18 (4) : 439-451.
  • 4Stein SW. Size distribution measurements of metered dose inhalers using Andersen Mark II cascade impactors [J]. lnt J Pharm, 1999, 186(1): 43-52.
  • 5de Boer AH, Gjaltema D, Hagedoorn P, et al. Characterization of inhalation aerosols: a critical evaluation of cascade impactor analysis and laser diffraction technique [J]. lnt J Pharm, 2002, 249 (1-2): 219-231.
  • 6Harris JA, Stein SW, Myrdal PB. Evaluation of the TSI aerosol irnpactor 3306/3321 system using a redesigned impactor stage with solution and suspension metered-dose inhalers EJ]. AAPS PharmSciTech, 2006, 7 (1) : E20.
  • 7WS1-(X-419)-2004Z,National Drug Standards(国家药品标准)[S].2004.
  • 8JX20090286,National Import Drug Standards(国家进口药品标准)[S].2009.
  • 9徐玉文,梁翠荣,谢元超,王志军.两种测定布地奈德气雾剂雾粒分布方法的比较[J].中国医药工业杂志,2013,44(9):921-924. 被引量:9

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...