介绍某电厂1号机组首次A级检查性检修期间化学监督检查的情况,对受热面结垢、积盐及氧化皮脱落等状况进行了分析和评价,对垢样分析方法进行了探讨。
This paper introduces the first A -level examination of the maintenance period of supervision and inspection of chemical conditionsthe in one power plant unit,analyses and evaluates on the heating surface deposition,salt accumulation and oxidation velamen desquamating,and discusses the method of scale sample.
出处
《安徽电力》
2011年第1期1-4,11,共5页
Anhui Electric Power
关键词
超临界机组
检修
盐类沉积
流动加速腐蚀
垢样分析
supercritical unit
maintenance
salts deposition
flow accelerated corrosion
scale sample analysis