摘要
在磷酸二铵装置成品冷却系统成功运行经验的基础上,理论推导出流化床冷却器的热量平衡式,并以实际操作数据加以验证。
Based on the successful operation of product cooling system of DAP plant, the author deduces theoretically the heat balance equation of fluidized bed cooler, and the equation is verified by practical data.
出处
《化工设计》
CAS
1999年第5期16-17,共2页
Chemical Engineering Design