期刊文献+

采用微波消解与ICP-MS法同时测定酱油中Pb和Cd 被引量:4

Simultaneous Determination of Pb and Cd in Sauce by Microwave Digestion and ICP-MS
下载PDF
导出
摘要 应用微波消解处理样品,采用In和Re元素作为内标,电感耦合等离子体质谱法(ICP-MS)同时测定样品中Pb、Cd。方法的检出限为Pb0.002mg/L,Cd0.001mg/L,精密度高于3%,回收率97%~103%。整个方法检出限低、简单、快速和准确。 Pb and Cd in sauce were determined simultaneously by ICP-MS,using microwave digestion for sample handling,In and Re as internal standard.The detection limit of Pb ad Cd were 0.002mg/L and 0.001mg/L respectively,the degree of precision was more than 3% and the recovery was 97%~103%.Therefore,this method is simple,rapid and accurate with low detection limit.
出处 《矿产综合利用》 CAS 2011年第2期47-48,共2页 Multipurpose Utilization of Mineral Resources
关键词 ICP-MS 微波消解 酱油 PB CD ICP-MS Microwave digestion Sauce Pb Cd
  • 相关文献

参考文献3

二级参考文献9

共引文献29

同被引文献49

引证文献4

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部