研制了碳纳米管微柱,建立了测定有机氯类农药的微柱固相萃取气相色谱-质谱法。样品泵入多壁碳纳米管微柱,8种有机氯类农药吸附保留到微柱,引入甲醇洗脱,气质联用选择离子监测方式检测洗脱液中有机氯类农药。考察了影响微柱固相萃取有机氯类农药的各种因素,包括样品流速、样品体积、洗脱剂种类、洗脱剂体积和碳纳米用量等。建立的方法适用于茶叶水提液中8种有机氯类农药分析,检出限0.015~0.25μg/kg。加标样品回收率74.5%~107.2%,相对标准偏差小于12%。
A method of determination of organochlorine pesticides(OCPs) by gas chromatography-mass spectrometry(GC-MS) was developed based on solid-phase extraction using self-made mini-column filled with multi-walled carbon nanotubes(MWCNTs).The preconcentration and clean-up of OCPs was carried out based on the adsorption retention of analytes on the MWCNTs via pumping the sample into the mini-column system.Methanol was introduced to elute the retained analytes for GC-MS detection using selected ion monitoring(SIM) mode.Important influence factors were studied in detail,such as sample flow rate,sample volume,eluent type,eluent volume and carbon nanotubes mass.The developed method was feasible to determine OCPs in tea with the limit of detection in the range of 0.015~0.25 μg/kg.Recoveries of the spiked tea sample were in the range of 76.5%~107.2% with relative standard deviations of no more than 12%.
出处
《食品科技》
CAS
北大核心
2011年第4期296-298,303,共4页
Food Science and Technology
基金
国家质检总局项目(2009IK131)
徐州市科技计划项目(XM08C026)
关键词
固相萃取
气相色谱-质谱法
有机氯类农药
碳纳米管
茶叶
solid-phase extraction
gas chromatography-mass spectrometry
organochlorine pesticides
carbon nanotubes
tea