期刊文献+

抗燃油油质异常原因分析与解决措施 被引量:6

Cause Analysis of Abnormal Quality of Fire-resistant Oil and Its Solutions
下载PDF
导出
摘要 成都金堂发电有限公司2×600 MW火力发电机组自投运来,抗燃油逐渐出现酸值升高、泡沫特性不合格、体积电阻率下降、颗粒污染物等级时有不合格等诸多问题。大修前对主设备进行检查发现诸多问题并分析油质劣化原因。采用功能不同的三台装置同时滤油,效果显著,经试验测试,抗燃油所有指标合格。因此提出防止抗燃油劣化的预见性管理措施。 Aiming at the problems of fire-resistant oil in electro-hydraulic control system of 2×600 MW thermoelectric generating set in Jintang Power Plant,the relevant equipment of EH high-pressure fire-resistant oil system during overhaul is inspected.The phenomenon and reasons are analyzed.Three devices with different functions are used to filter oil,and after the test,all the indexes of fire-resistant oil are up to standard.So the management measures to prevent the deterioration of fire-resistant oil are proposed.
作者 高为 李莉
出处 《四川电力技术》 2011年第2期82-86,共5页 Sichuan Electric Power Technology
关键词 抗燃油 油质劣化 原因分析 管理措施 fire-resistant oil oil deterioration reason analysis management measures