摘要
目的:评定质控金黄色葡萄球菌计数检测的不确定度,减少检测结果误差。方法:依据GB4789.10-2010,分析质控金黄色葡萄球菌计数结果的不确定度来源,并对检验结果取对数后评定其不确定度。结果:质控金黄色葡萄球菌含量为1.6×104~2.8×104 CFU/ml。本次实验的重复性限为1.27,复现性限为1.34。结论:不确定度的分析能有效掌握检测结果的可信程度和准确性。本次实验不确定度评定方法,也适合检测样品金黄色葡萄球菌计数结果的不确定度评定。
Objective:To assess uncertainty of Staphylococcus aureus count in the quality control inspection and reducing error.Methods:Analyzing source of the uncertainty of Staphylococcus aureus count in the quality control inspection result(according to GB4789.10-2010) and calculating the uncertainty of logarithm of the results.Results:The content of Staphylococcus aureus 1.6×104~2.8×104 CFU/ml in quality control.Repeatability limit of this experiment was 1.27,reproducibility limit was 1.34.Conclusion:The analysis can effectively ensure credibility and accuracy of the results.The method was also appropriate to the testing samples of uncertainty of Staphylococcus aureus count.
出处
《中国卫生检验杂志》
CAS
2011年第3期654-656,共3页
Chinese Journal of Health Laboratory Technology
关键词
金黄色葡萄球菌计数
不确定度
重复性
复现性
Staphylococcus aureus count
Uncertainty
Repeatability
Reproducibility