摘要
通过数据监测,对右江水电厂4台机组水导轴承运行中出现瓦温缓慢上升的问题进行分析,查找原因,并提出了不同的技术改造方案,对比后择优实施,既保证了水电厂的长期安全稳定运行,又为企业节省了成本。
Monitoring data had indicated slow temperature rise of turbine guide bearing bush at four units of Youjiang Hydropower Plant. Based on analysis of the causes, several technical upgrade schemes were compared before determination, so as to ensure long-term safe and stable operation of power plant with less cost.
出处
《广西水利水电》
2011年第2期53-54,57,共3页
Guangxi Water Resources & Hydropower Engineering
关键词
水导瓦温
冷却器
水导轴承
右江水电厂
Temperature of turbine guide bearing bush
cooler
turbine guide bearing
Youjiang Hydropower Plant