摘要 应用Marc软件仿真光刻胶熔融变形过程,研究热熔回流工艺参数对尺寸规格D×h为Φ500μm×66μm的微圆柱光刻胶熔融后微球形结构高度的影响.对仿真结果进行正交实验法分析,得出最佳工艺参数组合;对仿真结果进行单因素实验法分析,研究不同工艺参数对微球形结构高度的影响规律.结果表明,最佳工艺参数组合:加热速率1℃/s,加热温度110℃,保温时间45 min;工艺参数对微球形结构高度的影响顺序为:保温时间>加热速率>加热温度. In order to research the influence of thermal reflow processing parameters on the micro-spherical structure's height which is melted by the D×h(Φ500 μm×66 μm) micro-cylinder resist,the Marc software was applied to simulate resist melting and deforming processing.The ideal processing parameters combination was obtained by orthogonal experimental method and the single factor experimental method was utilized to study the effect law of different processing parameters on the height of micro-spherical structure.The results showed that the ideal processing parameters combination was 1 ℃/s for heating rate,110℃ for heating temperature and 45min for holding time;the significance of processing parameters on the micro-spherical structure's height can be ordered in holding timeheating rateheating temperature.
出处 《郑州大学学报(工学版)》 CAS 北大核心 2011年第2期37-41,共5页 Journal of Zhengzhou University(Engineering Science)
基金 国家自然科学基金外国青年学者项目(51050110138)
关键词 热熔回流 工艺参数 微球形结构 Marc仿真 thermal reflow processing parameter micro-spherical structure marc simulation
  • 相关文献

参考文献4

二级参考文献30

  • 1Santos A, Humyun M S, DE Juan E JR, et al. Preservation of the Inner Retina in Retinitis Pigmentosa, A Morphometric Analysis [J]. Arch Ophthalmol, 1997, 115(4): 511-515.
  • 2KIM S Y, SADDA S, PEARLMAN J, et al. Morphometric Analysis of the Macula in Eyes with Disciform Agerelated Macular Degeneration [J]. Retina, 2002, 22(4):471-477.
  • 3Humayun M S, Weiland J D and Fujll G Y, et al. Visual Per ception in a Blind Subject with a Chronic Microetectronie Reti nal Prosthesis [J]. Vision Research, 2003, 43 (24): 2573-2581.
  • 4Chow A Y, Chow V Y, Packo K H, et al. The Artificial Silicon Retina Microchip for the Treatment of Vision Loss from Retinitis Pigmentosa [J]. Arch Ophthalmol, 2004, 122 (4) : 460-469.
  • 5Peachey N S ,Chow A Y. Subretinal Implantation of Semiconductor-Based Photodiodes: Progress and Challenges[J]. J Rehabil Res Dev, 1999, 36(4): 371-376.
  • 6Mokwa W. MEMS Technologies for Epiretinal Stimulation of the Retina[J]. J Micromech Microeng, 2004,14:12-16.
  • 7Kook I, Hum C, Youngsuk Y, et al. Fabrication of Pyramid Shaped Three-Dimensional 8 × 8 Electrodes for Artificial Retina [J]. Sensors and Actuators A, 2006, 130-131:609-615.
  • 8Rodger D C, Fong A J, LI W, et al. High-Density Flexible Parylene-Based Multielectrode Arrays for Retinal and Spinal Cord Stimulation [C]// Transducers 2007. Lyon, France, 2007: 1385-1388.
  • 9He Q, Meng E, Tai Y C, et al. Parylene Neuro-Cages for Live Neural Networks Study [C]// The 12th IEEE International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers 2003). Boston, USA, 2003: 995-998.
  • 10Meng E, Tai Y C, Eeicson J, et al. Parylene Technology for Mechanically Robust Neuro-Cages[C]// Proceedings of 2003 Micro Total Analysis Systems. Squaw Valley, CA, 2003:1109-1112.

共引文献26

同被引文献3

  • 1OIKAWA M, IGA K, SANADA T, et al. Array of distributed- index planar micro-lenses prepared from ion-exchange tech- nique[J]. Japanese Journal of Applied Physics, 1981,20 (4) : 296 - 298.
  • 2KONG L B,CHEUNG C F,KWOK T C. Theoretical and ex- perimental analysis of the effect of error motions on surface generation in fast tool servo machining [ J ]. Precision Engi- neering ,2014 ( 38 ) :428 - 438.
  • 3YU D P, GAN S W,WONG Y S, et al. Optimized tool path generation for fast tool servo diamond turning of micro-struc- tured surfaces [J]. Advanced manufacture technology, 2012 (63) :1137 - 1152.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部