摘要
通过对华能南京电厂2 台300 MW 机组锅炉掺烧阳泉煤的实验室研究和实炉掺烧试验,得到锅炉掺烧阳泉煤对运行可靠性和经济性的影响,并对产生这些影响的因素进行了简要分析。结果表明试验是成功的,扩大了燃煤范围并降低了成本,取得了很好的经济效益。
Through laboratory research and on site testing on Yangquan coal blending firing on two 300 MW boilers in Huaneng Nanjing Power Plant,the impacts of coal blending firing on operation reliability and economics of boilers were obtained,and the factors leading to these impacts were briefly analyzed.The results showed that testing was successful,coal combustion ranges were expanded and cost was reduced with good economic benefit gained.
出处
《中国电力》
CSCD
北大核心
1999年第11期17-21,共5页
Electric Power
关键词
锅炉
可靠性
燃煤
电厂
boiler coal blending firing testing reliabi lity economics