摘要 为了给脉动生物反应器提供一个稳定可靠,且输出力量和工作行程可调的脉动源,设计并研制出一种新型直线电机;该电机采用动磁分体式结构,解决了该类电机输出力不平稳的问题,同时利用STC89C52为核心的控制模块,设计出正负脉冲变频电源,使脉动源输出压力达到160mmHg,输出流量达到100ml;经过反复的实验论证,此直线电机运行可靠,各项指标均已达到设计要求;与同类相比,该电机结构设计新颖,工作安全可靠,性价比高。 In this paper,a novel linear motor is designed and developed for pulse bioreactor,which is the pulsation source with stable output power and adjustable travel.Separable structure is used in the motor in order to solve the problem of unstable output power,at the same time,under the control of two-way pulse variable frequency power by the control module of STC89C52,so that the pressure pulse source output to 160mmHg,the output flow rate to 100mL.Through many trials,the motor was running stably and all indexes were meeting the requirements exactly.Compared with similar device,novel structure,operate safe and reliable,cost-effective are the prominent characteristics in this motor.
出处 《计算机测量与控制》 CSCD 北大核心 2011年第4期918-920,共3页 Computer Measurement &Control
基金 国家高技术研究发展计划(863计划)(2006AA02A138)
关键词 直线电机 正负脉冲变频电源 脉动生物反应器 STC89C52 linear motor two-way pulse variable frequency power pulse bioreactor STC89C52
  • 相关文献

参考文献3

二级参考文献15

  • 1徐秀林,张京航,梁伟,邹任玲,徐根林.人工心脏瓣膜质量及安全性评价[J].中国医疗器械杂志,2004,28(5):360-362. 被引量:9
  • 2林延昌,鱼洋,沈跃.基于PMAC控制卡的机器人控制软件设计[J].计算机测量与控制,2005,13(8):854-857. 被引量:5
  • 3gehinger J, Landeen LK, Alexander HG, et al. Development and characterization of tissue-engineered aortic valves[J]. Tissue Engineering, 2 O01,7 (1) : 9-19.
  • 4Schoen FJ, Levy RJ. Tissue heart valves: current challenges and future research perspections[J]. J Biomed Mater Res,1999,47(4) :439-465.
  • 5Girard PR,Nerem RM. Shear stress modulates endothelial cell morphology and F-actin organization through the regulation of focal adhesion associated proteins[J]. J Cell Physiol, 1995,163(1):179-193.
  • 6Mitsumata M, Fishel RS, Nerem RM, et al. Fluid shear stress stimulates platelet-derived growth factor expression in endothelial cells[J]. Am J Physiol,1993,265(1 Pt 2):H3-H8.
  • 7Jansson K, P, engtsson L, Swedenborg J, et al. In vitro endothelialization of bioprosthetic heart valves provides a cell monolayer with proliferative capacities and resistance to pulsatile flow[J]. J Thorac Cardiovasc Surg , 2001,121 : 108-115.
  • 8GB12279-90人工心脏瓣膜通用技术条件[S].国家技术监督局,1990.
  • 9Delta Tau Data System Inc.. PMAC USER'S MANUAL EM]. USA, Delta Tau Data System Inc. , 1999.
  • 10窦肇华.人体结构与功能[M].北京:人民卫生出版社,2005.