摘要
目的:建立高灵敏度的化学发光酶免疫分析法(CLEIA)检测睾酮。方法:包被抗体、标记抗原或包被抗原、标记抗体,用辣根过氧化物酶标记,鲁米诺增敏化学发光体系作为酶底物。结果:包被二抗、标记睾酮的方法灵敏度高、操作简便,灵敏度为0063ng/ml,睾酮浓度为10、50和100ng/ml时,批内变异58%~74%(n=20),批间变异为66%~87%(n=20),回收率为982%~104.0%。与5α二氢睾酮交叉反应为200%,与其它类固醇无明显交叉反应。此法与宝灵曼(BM)直接酶免疫分析试剂盒比较有较好的相关性,CLEIA=0915BM+0598ng/ml,n=128,r=0971,P<0001。结论:此法灵敏度高,有较好的准确性和重复性,与商品试剂盒有较好的相关性,适合临床应用。
Objective: To establish a chemiluminescent enzyme
immunoassay (CLEIA) for testosterone. Methods: Antibody was coated and antigen was
labeled or antigen was coated and antibody was labeled. Horseradish peroxidase was used as
a label and enhanced chemiluminescent system as substrate. Results: The method with
coated second antibody and labeled testosterone had high sensitivity and simple measures.
The sensitivity of the assay was 0.063 ng/ml. The testosterone was added to the steroidfree
serum at concentrations of 1.0, 5.0 and 10.0 ng/ml, the withinrun coefficients of variation were 5.
8%7.4%( n =20), and runtoruns' were 6.6%8.7%( n =2)respectively. The recovery rates were from
98.2% to 104.0%. The assay was not crossreacted significantly with other steroids except
5dihydrotestosterone with 20% cross reactivity. It correlated well with Boehringer Mannheim
enzyme immunoassay kit (BM) for testosterone. CLEIA=0.915 BM+0.598 ng/ml, n=128, r=0.971.
Conclusion: The chemiluminescent enzyme immunoassay has high sensitivity, good accuracy,
repeatability and correlation with commercial kit. The method is helpful to clinical laboratory
diagnosis.
出处
《中国免疫学杂志》
CAS
CSCD
北大核心
1999年第7期308-310,共3页
Chinese Journal of Immunology
关键词
睾酮
鲁米诺
CLEIA
酶免疫分析
Chemiluminescent enzyme immunoassayTestosteroneLuminol