期刊文献+

心阻抗血流图法与热稀释法测定大鼠心输出量的比较 被引量:3

Comparison between Inipedance-Cardiorheography and Thermodilution Method in the Measurement of Cardiac Output
下载PDF
导出
摘要 应用心阻抗血流图法测31只大鼠心输出量,与热稀释法测得结果呈高度相关(r=0.99,P<0.01)。说明心阻抗血流图法测大鼠的心输出量是可靠的,本实验测得大白鼠血液的平均电阻率(ρ值)为146±6.73Ω·cm(x±s)。 In the present study conductance (p) of blood in rats was measured and the cardiac output measured by impedance-iardiorheography was compared with wiih that measured by thermodilution method in 31 rats.The results showed that the mean conductance (p) of blood in rats was 146±6.73Ω·cm(x±s).The cardiac output measured by impedance-cardiorheography was highly correlated with that measured by thermodilution method (r=0.99,P<0.01).It is suggested that the impedance-cardiorheography is reliable in the measurement of cardiac output.
出处 《同济医科大学学报》 CAS CSCD 北大核心 1990年第3期174-176,共3页 Acta Universitatis Medicinae Tongji
关键词 心输出量 心电描记术 热稀释法 cardiography, impedance thermodilution cardiac output
  • 相关文献

参考文献1

  • 1[苏]N·M·特拉赫金别尔格等 编著,李甡等.毒理实验中实验动物各种指标的正常值[M]人民卫生出版社,1984.

同被引文献6

引证文献3

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部