摘要 目的探讨双源CT双能量技术在前交叉韧带损伤诊断中的应用价值。方法分析我院经关节镜手术证实的8例患者的双源CT资料。所有患者行多平面重建、容积再现等二维、三维重建及双源CT上肌腱模式重建,并将双能特征与其关节镜结果进行对照分析。结果诊断前交叉韧带损伤6例,全部与关节镜结果一致;诊断前交叉韧带正常2例,其中1例与关节镜结果一致、1例漏诊;总体诊断符合率为87.5%(7/8)。损伤的前交叉韧带表现为双能肌腱模式下双能染色低于患者对侧正常的前交叉韧带。结论双能量染色减少可能是前交叉韧带损伤诊断的新的征象。 Objective To explore the diagnostic value of the dual-energy technique with dual-source computed tomography (DSCT) for anterior cruciate ligament injuries.Methods The clinical data of 8 patients with arthroscopic results were retrospectively reviewed.All patients underwent two-and three-dimensional imaging by multiplanar reconstruction,volume rendering,and tendon mode on DSCT.Dual-energy characteristics were compared with arthroscopic results.Results Six patients who were arthroscopically diagnosed as anterior cruciate ligament injuries,all of them were also correctly diagnosed by DSCT.Two patients who were arthroscopically diagnosed as normal,one was also diagnosed as normal by DSCT and the other was misdiagnosed.The overall agreement rate was 87.5% (7/8).Under the dual energy tendon mode,the dual energy staining of the injured anterior cruciate ligament was lower than that of the contralateral normal cruciate ligament of the patient.Conclusion The staining diminution in DSCT imaging may be a new feature that can be used to effectively diagnose anterior cruciate ligament injury.
出处 《中国医学科学院学报》 CAS CSCD 北大核心 2010年第6期663-665,720,共4页 Acta Academiae Medicinae Sinicae
关键词 X线计算机 体层摄影术 双能量 前交叉韧带 损伤 X-ray computed tomography dual-energy anterior cruciate ligament injury
  • 相关文献

参考文献8

  • 1Fuchs S,Chylarecki C.Sonographic evaluation of ACL rupture signs compared to arthroscopic findings in acutely injured knees[J].Ultrasound Med Biol,2002,28(2):149-154.
  • 2Craig JG,Go L,Blechinger J,et al.Three-tesla imaging of the knee:initial experience[J].Skeletal Radiol,2005,34(8):453-461.
  • 3Tung GA,Davis LM,Wiggins ME,et al.Tears of the anterior cruciate ligament:primary and secondary signs at MR imaging[J].Radiology,1993,188(3):661-667.
  • 4Lundberg M,Odensten M,Thuomas KA,et al.The diagnostic validity of magnetic resonance imaging in acute knee injuries with hemarthrosis[J].Int J Sports Med,1996,17(3):218-222.
  • 5Segawa H,Omori G,Koga Y.Long-term result of non-operative treatment of anterior cruciate ligament injury[J].Knee,2001,8(1):5-11.
  • 6Umans H,Wimpfheimer O,Haramati N,et al.Diagnosis of partial tears of the anterior cruciate ligament of the knee:value of MR imaging[J].AJR,1995,165(4):893-897.
  • 7Johnson TR,Krauss B,Sedlmair M,et al.Material differentiation by dual energy CT:initial experience[J].Eur Radiol,2007,17:1510-1517.
  • 8孙丛,柳澄,王锡明,王涛,王道平,邓凯.双能CT成像在显示膝关节韧带中的价值[J].中国医学影像技术,2008,24(9):1323-1325. 被引量:30

二级参考文献8

  • 1Vande Berg BC, Lecouvet FE, Poilvache P, et al. Spiral CT arthrography of the postoperative knee. Semin Musculoskelet Radiol, 2002,6(1):47-55.
  • 2Buckwalter KA. CT Arthrography. Clin Sports Med, 2006,25 (4) :899-915.
  • 3Johnson TR, Krauss B, Sedlmair M, et al. Material differentiation by dual energy cm:initial experience. Eur Radiol, 2007, 17(6): 1510-1517.
  • 4Graser A, Johnson TR, Bader M, et al. Dual energy CT characterization of urinary calculi: initial in vitro and clinical experience. Invest Radiol, 2008,43(2) :112-119.
  • 5Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol, 2006, 16(2) :256-268.
  • 6Vande Berg BC, Lecouvet FE, Maldague B, et al. MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrographyguided analysis. Eur Radiol, 2004,14 (2):208-214.
  • 7Gold GE, Busse RF, Beehler C, et al. lsotropic MRI of the knee with 3D fast spin echo extended echo-train acquisition (XETA): initial experience. AJR Am J Roentgenol, 2007, 188(5): 1287 1293.
  • 8Fayad LM, Rosenthal EH, Morrison WB, et al. Anterior crueiate ligament volume: analysis of gender differences. J Magn Reson Imaging, 2008,27(1) :218-223.

共引文献29

同被引文献64

  • 1Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol, 2006,16(2):256-268.
  • 2Schenzle JC, Sommer WH, Neumaier K, et al. Dual energy CT of the chest: How about the dose? Invest Radiol, 2010,45(6):347-353.
  • 3Robinson E, Babb J, Chandarana H, et al. Dual source dual energy MDCT: Comparison of 80 kVp and weighted average 120 kVp data for conspicuity of hypo-vascular liver metastases. Invest Radiol, 2010,45(7):413-418.
  • 4Boden BP, Osbahr DC. High-risk stress fractures: Evaluation and treatment. J Am Acad Orthop Surg, 2000,8(6):344-353.
  • 5Guggenberger R, Gnannt R, Hodler J, et al. Diagnostic performance of dual-energy CT for the detection of traumatic bone marrow lesions in the ankle: comparison with MR imaging. Radiology, 2012,264(1):164-173.
  • 6Pache G, Krauss B, Strohm P, et al. Dual-energy CT virtual noncalcium technique: Detecting posttraumatic bone marrow lesions--feasibility study. Radiology, 2010,256(2):617-624.
  • 7Johnson TR, Krauss B, Sedlmair M, et al. Material differentiation by dual energy CT: Initial experience. Eur Radiol, 2007,17(6):1510-1517.
  • 8Sun C, Miao F, Wang XM, et al. An initial qualitative study of dual-energy CT in the knee ligaments. Surg Radiol Anat, 2008,30(5):443-447.
  • 9Choi HK, Mount DB, Reginato AM. Pathogenesis of gout. Ann Intern Med. 2005,143(7):499-516.
  • 10Graser A, Johnson TR, Bader M, et al. Dual energy CT characterization of urinary calculi: Initial in vitro and clinical experience. Invest Radiol, 2008,43(2):112-119.

引证文献6

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部