摘要 目的:总结分析膝后叉韧带胫骨止点撕脱性骨折临床疗效。方法:对2001年1月~2008年10月间共收治的27例膝后叉韧带胫骨止点撕脱性骨折用可吸收螺钉固定进行回顾性分析。结果:27例均获得随防,时间8个月~2年,平均1.5年,优15例、良7例、可5例、差0例。结论:可吸收螺钉治疗膝后叉韧带胫骨止点撕脱骨折为临床满意疗效的方法之一。 Cbjective to summarize and analysis the curative effect of avulsion fradture in PCL s ending poilt Method retrospective analysis 27cases of avulsion fracture in PCL anding point Which were treated by absorptive screw from january2001 to October2010. Results All of 27 eases were followed up from 8months to 2years averaging 1.5 years excellent 15 cases good 7 cases aprove 5cases ineffective 0cases Conclusions Using absorptive screw to treat avulsion fracture in PCL ending point is one of the good methods in well recovery.
作者 章仕元
出处 《求医问药(下半月刊)》 2011年第3期99-99,72,共2页 Seek Medical and Ask The Medicine
  • 相关文献

参考文献3

二级参考文献14

  • 1高彦平,吴宇峰,邱桂春,赵卫东,苏培基,李义凯.前交叉韧带胫骨棘止点撕脱骨折的现状与思考[J].中华创伤骨科杂志,2005,7(3):272-274. 被引量:26
  • 2Alfredo Schiavone P, Giuseppe M, Marlo T. Arthosocopic treatment of malunited and nonunited avulsion fractures of the anterior tibial spine[ J]. Arthroscopy, 1998, 14(3 ) :223 - 240.
  • 3Stephen Y. C. H. An easy and effective method for reattaching an anterior cruciate ligament avulsion fracture from the tibial eminence[ J ].Arthroscopy,200d.,20( 1 ) :96 - 100.
  • 4Davies E. M. , Mclaren M.I. Type Ⅲ tibial spine avulsions treated with arthosocopic acutrak screw reattachment[ J]. Clin Orthop,2001.19(7 ) :205 -208.
  • 5Mehmet S. B, Ilksen G,Cengiz Y. Arthosocopic fixation of intercondylar eminence fracture using a 4-poral technique [ J ]. Arthroscopy,2001,17(5 ) :450 -460.
  • 6Vladimir S, Matjaz V. Antergrade arthosocopic fixation of avulsion fracture of the tibial eminence with a cannulated screw : five-year resuits[J]. Arthroscopy, 2003,19( 1 ): 54-61.
  • 7Minider S. K,Edward S. F, Lyle J. M. Laxity and functional outcome arthosocopic reduction and internal fixation of dispalced tibial spine fracture in children [ J]. Arthroscopy,2003,19(10): 1085 - 1090.
  • 8Clancy WGJr, Shelbourne KD, Zoellner GB, et al. Treatment of knee joint instability secondary to rupture of posterior cruciate ligament; repaort of a new procedure. Bone Joint Surg (Am), 1983,65:310.
  • 9Rokkanen P, Bostman O, Vainionpaa S, et al. Absorbable devices in the fixation of fractures. J Trauma, 1996, 40 (3) : 123.
  • 10Paivarinta U, Bostman O, Majola A, et al. Intraosseous cellular response to biodegradable fracture fixation screws made of poglycolide. Arch Orthop Trauma Surg, 1993, 112 (2) : 71.

共引文献57

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部