摘要 墙体保温有外保温、内保温、夹心保温3种形式,各有利弊。山西多数地区位于寒冷地区,且具有丰富的煤矸石资源,利用烧结煤矸石多孔砖墙进行承重,并在外墙内侧加无机保温砂浆,建造6层以下的多层建筑,既可以满足寒冷地区节能要求,又具有很好的社会效益和经济效益。选择山西省3个烧结煤矸石厂生产的多孔砖,进行3种不同构造做法的墙体传热系数研究,得出了烧结煤矸石多孔砖墙加50 mm厚保温砂浆的墙体内保温,完全可以满足山西省忻州以南地区65%的节能要求。 The wall thermal insulation includes the internal thermal insulation,the external thermal insulation and the interlayer insulation.Each method has its own advantages and disadvantages.Because there are plenty of resources of coal gangue in Shanxi where most of places are in cold region,the sintered coal gangue brick forming the bearing walls combined with the inorganic thermal insulation mortar are used to build the six-storey high building,which meets the need of the energy conservation,as well as good social and economic benefits in cold regions.Three heat transfer coefficients of three different sintered coal gangue brick produced in factories are analyzed by three different manufacturing methods.The conclusion is that the internal thermal insulation made of the sintered coal gangue brick and 50mm thermal insulation mortar could totally reach the requirement of 65% energy conservation in the south of Xinzhou in Shanxi province.
作者 宋岩丽
出处 《建筑节能》 CAS 2011年第4期42-45,共4页 BUILDING ENERGY EFFICIENCY
关键词 寒冷地区 烧结煤矸石多孔砖 墙体内保温 传热系数 cold region sintered coal gangue brick internal thermal insulation of the wall heat transfer coefficient
  • 相关文献

同被引文献9

  • 1DBJ04-216--2006,山西民用建筑节能设计标准[S].
  • 2Dylewski Robert, Adamczyk Janusz. Economic and environmental benefits of thermal insulation ofbuilding external walls [ J ]. Building and Environment, 2011, 43(9) : 2414-2421.
  • 3Bekkouche S M A, Benouaz T, Yaiche M R. Introduction to control of solar gain and internal temperatures by thermal insulation, proper ori[J]. Energy and Buildings, 2011, 43(9): 2414-2421.
  • 4吴振洲.DBJ04-242-2012,居住建筑节能设计标准[S].太原:山西省住房和城乡建设厅,2012.
  • 5Yin Yonggao, Zhang Xiaosong. A new method for determining coupled heat and mass transfer coefficients between air and liquid desiccant [J]. International Journal of Heat and Mass Transfer, 2008,51 (13) : 3287-3297.
  • 6Kawahara Toshio, Fujii Tomohiro, Emoto Masahiko. Double peltier current lead for heat leak reduction at the terminals for superconducting direct current applications [ J ]. Ieee Transactions on Applied Superconductivity, 2010(21) : 1070-1073.
  • 7王力雄.建筑节能[M].第2版.北京:中国建筑工业出版社,2009.
  • 8田斌守,章岩,杨树新,李玉玺.节能65%目标与自保温混凝土砌块[J].混凝土与水泥制品,2008(1):49-52. 被引量:23
  • 9李文秀.利用煤矸石制砖的环境影响分析[J].洁净煤技术,2008,14(3):93-95. 被引量:3

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部