血液分析仪白细胞不分类的影响因素及处理方法 被引量:10

EXPLORE THE INFLUENCING FACTORS INDUCED BACKMAN COUNTER DECLASSIFICATION OF WHITE CELL AND THE MEASURES TO MANAGE IT
下载PDF
导出
摘要 目的探讨血液分析仪白细胞不分类的影响因素及处理方法。方法对白细胞不分类的标本做胆红素含量测定;对不分类标本用稀释液稀释后再用仪器检测并测定稀释前后红细胞渗透脆性;选取40份标本制片染色进行显微镜白细胞分类并将结果与稀释后标本的仪器法白细胞分类结果分别进行统计分析。结果红细胞渗透脆性降低、红细胞碎片及低温度等多方因素共同作用出现白细胞不分类的现象;稀释法仪器白细胞分类结果与显微镜手工法白细胞分类结果的差异无统计学意义(p>0.05)。结论影响白细胞不分类的因素是多样的;对不分类标本用稀释法(用稀释液1:1稀释后再作仪器分析)可得到分类数据;手工法与稀释法对白细胞分类影响无显著性差异,可用稀释法代替手工法分类白细胞。 Objective To explore the influencing factors induced Backman Counter declassification of white cell and the measures to manage it.Methods The declassification white cell specimens were determined for bilirubin;dilute the declassification specimens with diluent then mensurate its erythrocyte osmotic fragility before and after dilution;select 40 such specimens to be stained and undergoing white cell classification under microscope,then compare the outcomes with that derived from diluted specimen determined by blood counter and make statistic analysis.Results Erythrocyte osmotic fragility was reduced.Interaction of red blood cell debris and low temperature and various factors induced the phenomenon of white cell declassification.The outcomes of white cell classification under microscope and out comes from diluted specimen determined by blood counter has not significant difference(p0.05).Conclusion Classification of white blood cells can be affected by various factors;by means of dilution,classify data can derived from declassification specimen(diluted 1:1 by diluents,then determined with instrument);manual method and the dilution effect on the WBC has no significant difference,so dilution method can be used instead of manual classification of white blood cells.
出处 《现代医院》 2011年第3期67-69,共3页 Modern Hospitals
关键词 LH750血液分析仪 白细胞不分类 红细胞渗透脆性 手工法 Beckman Counter LH750 Declassification of white blood cells Erythrocyte osmotic fragility Manual method
  • 相关文献

参考文献7

二级参考文献12

  • 1孙大公 李玉梅.红细胞膜结构的改变对红细胞脆性的影响.医学生物力学,2000,15(2):100-100.
  • 2中华人民共和国卫生部医政司编.《全国临床检验操作规程》(第2版)[M].南京:东南大学出版社,1997.48-50.
  • 3中华人民共和国卫生部医政司编.全国临床检验操作规程(第2版)[M].南京:东南大学出版社,1997.48-50.
  • 4BulgenA 李红丽 张镇西.应用VCS技术的白细胞分类和计数[J].激光生物学报,1997,6(4):1247-1247.
  • 5李辉 雷汉题 李世新.CoulterMaxm全自动血细胞分析仪白细胞五项分类的评价及应用体会[J].实用医学检验杂志,1996,3(4):18-18.
  • 6叶应妩;王毓三.全国临床检验操作规程,1997.
  • 7Beckman Coulter MAXM/MAXM With Autoloader Operator,s Guide.
  • 8从玉隆.当代血液分析技术与临床,1997.
  • 9李福林,杨丽琼.血细胞分析仪白细胞计数结果假性增高和分类异常的原因及处理方法的探讨[J].陕西医学检验,1998,13(3):57-58. 被引量:3
  • 10谢卫民,樊云蓉.应用全自动血细胞分析仪对重症黄疸型肝炎病人白细胞的检测[J].湖南医科大学学报,1999,24(4):390-390. 被引量:6

共引文献36

同被引文献64

引证文献10

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部