期刊文献+

64排螺旋CT冠脉成像与冠脉造影的比较 被引量:4

Comparison of 64-slice spiral CT angiography and coronary angiography in diagnosis of coronary heart disease
原文传递
导出
摘要 目的探讨64排螺旋CT冠脉成像与冠脉造影对冠心病诊断的比较。方法对269例冠心病患者进行MSCT检查后进行冠状动脉造影检查,观察两种检查方法血管狭窄符合率。结果冠状动脉造影与MSCT检查的符合率95.16%。结论 64排螺旋CT冠脉成像安全、简便和无创伤。具有扫描速度更快,时间和空间分辨率高,对冠状动脉疾病具有较大的实用价值。 Objective To investigate the 64-slice spiral CT angiography and coronary angiography for coronary heart disease diagnosis.Methods Totally 269 patients with coronary heart disease after MSCT coronary angiography examination,observed two methods of stenosis coincidence rate.Results MSCT coronary angiography examinations with 95.16% compliance rate.Conclusions 64 slice spiral CT coronary angiography is safe,simple and noninvasive.With a scanning speed,time and space,high resolution,for coronary artery disease diagnosis have greater practical value.
出处 《医药论坛杂志》 2011年第3期75-76,共2页 Journal of Medical Forum
关键词 螺旋CT冠脉成像 冠脉造影 冠心病 诊断比较 Spiral CT coronary angiography Coronary angiography Coronary heart disease Diagnosis compared
  • 相关文献

参考文献5

二级参考文献24

  • 1姜荣,吴晓华,贺文.心率波动对多层螺旋CT冠脉造影图像质量的影响[J].中国医学影像技术,2004,20(10):1574-1576. 被引量:49
  • 2龚艳君,霍勇.64排CT冠状动脉成像的临床应用现况[J].中国介入心脏病学杂志,2005,13(6):416-416. 被引量:26
  • 3Ennedy JW.Complications associated with cardiac catheterization and angiography[J].Cath Cardiovasc Diagn,1982,8:5-11.
  • 4Hong C, Becker CR,Huber A,et al. ECG-gated reconstructed multi-detecter row CT coronary angiography:effect of varying trigger delay on image quality[J]. Radiology,2001,220:712-717.
  • 5Nieman K,Creasing BJ,Van Geuns RJ,et al.Uesfulness of multislice computed tomography fordetedcting obstructive coronary disease[J].Am J Cardionl,2002,89:913-918.
  • 6Kopp AF, Schroder S, Kuettner A, et al.Coronary arteries:retrospectively ECG-gated multi-detecter row CT angiography with selective optimization of the imagine reconstruction window[J].Radiology,2001,221:683-688.
  • 7Hoffman MBM, Wickline SA, Lorenz CH. Quantification of in-planemotion of the coronary arteries during the cardiac cycle:Implications for acquisition window duration for MR flow quantification[J].J Magn Reson Imaging,1998,8:568-576.
  • 8Nieman K,Oudkerk M,rensing BJ,et al.Coronary angiography with multi-slice computed tomograpgy[J].Lancet,2001,357(9256):599-603.
  • 9Abbara S,Cury RC,Nieman K,et al.Noninvasive evaluation of cardiac veins with 16-MDCT angiography[J].Am J Roentgenol,2005,185(4):1001-1006.
  • 10Hong C,becker CR,Huber A,et al.ECG-gated reconstructed multi-detector row CT coronary angiography:effect of varying trigger delay on image quality[J].Radiology,2001,220(3):712-717.

共引文献68

同被引文献24

引证文献4

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部