期刊文献+

人工心脏的无传感器无刷直流电机闭环调速系统 被引量:4

Closed Loop Speed Regulation System of Sensorless Brushless DC Motor for Artificial Heart
下载PDF
导出
摘要 介绍了一种用于人工心脏叶轮血泵的无传感器无刷直流电机闭环调速系统,该系统借助于先进的电机驱动专用集成电路 M L4428 ,实现了电机自起动,反电势检测和闭环速度调节等功能这不仅使系统控制特性及可靠性均得到提高,并且所用元件减少。 The design of the closed loop speed regulation system of sensorless bruchless DC motor for artificial heart impeller blood pump is introduced. With the help of advanced motor controller ML4428 IC, the system has realized the functions of starting ,back-EMF sensing and controlling speed ,resulting not only in improvement of the control system reliability and performance property,but also in reduction of system volume and number of components. The paper fully details the basic design principle of the system and the theoretical calculation formulae of components. In the end , the experimental results of the closed loop speed regulation system is given which proves that the system is of good speed regulation characteristics.
作者 曾培
出处 《江苏理工大学学报(自然科学版)》 1999年第5期40-43,共4页 Journal of Jiangsu University of Science and Technology(Natural Science)
基金 国家自然科学基金 国家教委博士点基金
关键词 人工心脏 无刷 直流电机 闭环调速系统 artificial heart brushless DC motor closed loop speed regulation
  • 相关文献

参考文献3

二级参考文献5

共引文献18

同被引文献31

  • 1Li GR, Ma WG, Zhu XD, et al. Preliminary study on an introaortic pump driven by a distant rotary magnet. ASAIO Journal, 2000; 46:151.
  • 2Weiss WJ. Recent improvement in a completely implanted total artificial heart. ASAIO Journal, 1996; 42:342.
  • 3Nose Y. Can we develop a total implantable rotary blood pump? Artificial Organs, 1995; 19(7):561.
  • 4Mitamura Y. Development of the valvo pump: An axial flow pump implanted at the heart valve position. Artificial Organs, 1999; 23:566.
  • 5Li HD, Chan WK. Inverse design and CFD investigation of blood pump impeller. Critical Reviews in Biomedical Engineering, 2000;28(1):75.
  • 6Burgreen GW, Antaki JF, Wu J, et al. CFD-based design optimization of the UoP streamliner rotary blood pump. Annals of Biomedical Engineering, 2000; 28(1):81.
  • 7Tsukiya T. Performances of a newly developed implantable centrifugal blood pump. ASAIO Journal, 2000; 46(2):171.
  • 8Nojiri C, Kijima T, Naekawa J, et al. More than one year continuous operation of a centrifugal pump with a magnetically suspended impeller. ASAIO Journal, 1997;43:548.
  • 9Mitamura Y. Durable, non-power consumptive, and simple seal for rotary blood pumps. ASAIO Journal, 2000; 46(2):157.
  • 10Xu LY, Fu MH. Computer modeling of interactions of an electric motor, circulatory system, and rotary blood pump. ASAIO Journal, 2000; 46(5):604.

引证文献4

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部