摘要 目的介绍一种适合复杂性胫腓骨骨折的治疗方法。方法本组54例开放性和(或)粉碎性胫腓骨骨折的病例,采用可吸收螺钉加外固定支架固定的方法治疗,同时常规行植骨术。结果 44例(81.5%)达到解剖复位,其余达到功能复位,骨折全部愈合,临床愈合时间4~14个月,平均6.5个月。随访10~24个月,平均13个月。按Johner-Wruhs评分标准,优51例,良3例。结论该方法创伤小,固定可靠,安全经济,值得推广应用。 Objective To introduce a technique for treating the complicated fracture of tibia and fibula. Methods Fifty - four cases of opened and/or comminuted fracture of tibia and fibula were treated by internal absorbable screws fixation with external skeletal trestle fixation, at the same time underwent the conventional bone graft. Results There were 44 cases ( 81. 5% ) having anatomic reduction, and the others having approximately anatomic reduction,All the bone fracture healed good, the clinical healing time of bone fracture was 4 - 14 months(average time of 6.5 months). Fifty - four cases were followed - up for 10 - 24 months ( average time of 13 months). Accerding to Johner - Wruhs standard,51 cases were excellent,3 cases were good. Conclusion The method has many advantages such as mininal damage , reliable effect, safety and low cost , and it is worth promoting the application.
出处 《河北医科大学学报》 CAS 2011年第3期283-285,共3页 Journal of Hebei Medical University
关键词 可吸收性植入物 外固定器 胫骨骨折 absorbable implants external fixators tibial fractures
  • 相关文献

参考文献6

二级参考文献30

共引文献41

同被引文献49

  • 1马巍,闵若良,陈秋,马瑞雪.自增强可吸收内固定治疗儿童肘部骨折[J].中华小儿外科杂志,2006,27(4):191-193. 被引量:10
  • 2熊名副,肖锐.可吸收螺钉内固定治疗儿童胫骨斜形骨折15例[J].江西中医药,2007,38(9):51-51. 被引量:4
  • 3Hollinger JO, Battistore GC. Biodgradable bore repair materi- als:Synthetic polymers and ceramics. Clin Orthop Relat Res, 1986,207 : 290-335.
  • 4Fu D, Xiao B, Yang S. Open reduction and bioabsorbable pin fixation for late presenting irreducible supracondylar humeral fracture in chilren. Int Orthop, 2011,35 (5) : 725-730.
  • 5Stewart RL, Cox JT, Volgas D,et al. The use of a biodegrad- able,load-bearing scaffold as a carrier for antibiotics in an in- fected open fracture model. J Orthop Trauma, 2010, 24(9): 587-591.
  • 6Klos K, Rausch S, Loffler M,et al. A biomechanical compari- son of a biodegradable volar locked plate with two titanium volar locked plates in a distal radius fracture model. J Trauma, 2010,68(4) :984-991.
  • 7Zhang J, Ebraheim N, Laus GE, et al. A comparison of absorbable screws and metallic plates in treating calcaneal fractures:a prospective randomized trial. J Trauma Acute Care Surg,2012,72(2) : 106-110.
  • 8Bostman O, Hirvensalo E, Vainionpaa S, et al. Ankle fracture treated using biodegradable intenal fixation. Clin Orthop Relat Res, 1989,238:195-203.
  • 9Mayberry JC, Terhes JT, Ellis TJ, et al. Absorbable plates for rib fracture repair., preliminary experience. J Trauma, 2003, 55(5) :835-839.
  • 10Bili e R, Kolundzi e R, Anticevi e D. Absorbable implants in surgical correction of a capitellar malunion in an 11-year-old a case report. J Orthop Trauma, 2006,20 (1) : 66-69.

引证文献5

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部