期刊文献+

近视度数对LASIK术后对比敏感度变化的影响 被引量:5

Effect of myopia diopter on the changes of contrast sensitivity after LASIK
下载PDF
导出
摘要 目的:探讨准分子激光原位角膜磨镶术(LASIK)后远方对比敏感度的变化。方法:使用美国Optec6500对比敏感度测试仪,对58例112眼接受LASIK治疗的近视患者,按等值球镜分组,低中度近视组:<-6.00D;高度近视组-6.00~-9.00D和超高度近视组>-9.00D。分别于术前、术后1mo和3mo检查空间频率为1.5,3.0,6.0,12.0,18.0周/度(cycle/degree,c/d)的远方对比敏感度,并进行统计学分析。结果:LASIK术后1mo,低中度近视组术眼远方对比敏感度在1.5,3.0及12.0c/d空间频率的下降有统计学意义;高度近视组术眼远方对比敏感度在6.0及18.0c/d空间频率的下降有统计学意义;超高度近视组术眼远方对比敏感度在所有空间频率的下降均有统计学意义。术后3mo,3组对比敏感度在各个空间频率上有明显恢复,接近术前水平。其中在3.0及12.0c/d空间频率的超高度近视组比低中度近视组下降幅度大。在18.0c/d空间频率的超高度近视组比高度近视组下降幅度大。结论:LASIK术后1mo内,近视度数高者,远方对比敏感度下降明显,并随着时间的推移逐渐恢复。 AIM:To evaluate far contrast sensitivity function before and after myopic laser in situ keratomileusis(LASIK).METHODS:With test chart,far contrast sensitivity was measured in randomly selected 58 subjects 112 eyes before,1 month and 3 months after LASIK.The patients were assigned to three different groups according to the mean spherical equivalent.Mean spherical equivalent of low/moderate myopia group was under-6.00D,average(-4.22±1.24)DS,mean spherical equivalent of high myopia group was-6.00--9.00 D,average(-6.98±1.42)DS,and mean spherical equivalent of superhigh myopia group was over-9.00 D,average(-10.88±1.36)DS.The contrast sensitivity was measured at 1.5,3.0,6.0,12.0 and 18.0 cycles per degree(c/d)spatial frequency respectively and comparison was made in them.RESULTS:There was a general reduction in far contrast sensitivity of superhigh myopia in all spatial frequencies at postoperative 1 month compared with the preoperative contrast sensitivity.The group(〈6.00D)preoperative and postoperative contrast sensitivity did not differ at 1 month in all spatial frequency.Descendent rates of far contrast sensitivity in superhigh myopia group were larger than that in low/moderate myopia group at 3.0,12.0c/d(P〈0.01),and that in superhigh myopia group were larger than that of in high myopia group at 18.0c/d(P〈0.01).There were no siginificant difference between three groups three months after LASIK(P〉0.05),and far contrast sensitivity was near preoperational level.CONCLUSION:One month after LASIK,the higher myopia has obvious decrease of far contrast sensitivity.
出处 《国际眼科杂志》 CAS 2011年第4期628-630,共3页 International Eye Science
关键词 准分子激光原位角膜磨镶术 近视 远方 对比敏感度 laser in situ keratomileusis myopia far contrast sensitivity
  • 相关文献

参考文献7

  • 1冯宇宁,方学军,于芳芳,金鑫,杨帆.切削深度对LASIK术后对比敏感度变化的影响[J].中国实用眼科杂志,2007,25(1):44-46. 被引量:3
  • 2Oshika T, Miyata K, Tokunaga T, et al. Higher order wavefront aberrations of cornea and magnitude of refractive correction in laser in situ keratomileusis. Ophthalmology 2002 ; 109(6) : 1154-1158.
  • 3Collins MJ, Buehren T. Retinal image quality, reading and myopia. Vis Res 2006;46(1-2) :196-215.
  • 4Stoimenova BD. The Effect of myopia on contrast thresholds. Invest Ophthalmol VJs Sci 2007 ;48 (5) :2371-2374.
  • 5|fiou SW, Chiu CJ. Myopia and contrast sensitivity function. Curtr Eye Res 2001 ;22(2) :81-84.
  • 6傅智伏,张铭志,李晓芳,罗陈川,张晟,王朱影.近视眼黄斑区视网膜色素上皮层厚度及形态与对比敏感度的联系[J].眼视光学杂志,2005,7(3):185-188. 被引量:7
  • 7Neeracher B, Senn P, Schipper 1. Glare sensitivity and optical side effects 1 year after photorefractive keratectomy and laser in situ ker- atomileusis.J Lhtaract Refract Surg 2004 ;30(8 ) : 1696-1701.

二级参考文献15

  • 1Thomas T. Norton. Spatial vision [A]. In: Thomas T norton editor.The psychophysical measurement of visual function[M]. New York:Susan F.Pioli U.S.A,2002.217- 288.
  • 2Arthur P. Gingurg, a new constrast sensitivity test chart[J]. Am J Optic Physiol Optom,1984,61(4):403-407.
  • 3Jindra LF, Zemon V. Constrast sensitivity testing: a more complete assessment of vision[J]. J Cataract Refiact Surg, 1989,15 (2) :141-148.
  • 4Kleiner RC,EngerC,Alexander MF,et al. Contrest sensitivity in agerelated macular degeneration[J]. Arch Ophthalmol January, 1988,106(1) :55 - 57.
  • 5Kawabata H, Adachi-Usami E. Multifocal electroretinogram in myopia [J]. Invest Ophthalmol Vis Sci, 1997,38(13) :2844 - 2851.
  • 6McCarty CA, Tailor HR. Editorial:Myopiaandvision2020[J]. AmJ Ophthalmol, 2000,129(4) :525 -527.
  • 7Lin LL, Shih YF , Tsaib CB , et al . Epidemiologyic study of ocular refraction among schoolchildren in Taiwan in 1995[J]. Optom Vis Sci,1999,76(5) :275 - 281.
  • 8Lin LK, Chen CJ, Hung PT, et al. National-wide survey of myopia among schoolchildren in Taiwan 1986 [J]. Acta Ophthalmol Suppl Copenh, 1988,185(5) :29 - 33.
  • 9Tano Y. Pathologic myopia: where are we now? [J]. Am J Ophthalmol,2002,134(5):645-660.
  • 10王铮,陈家祺,杨斌,龙时先,吴德正,刘华.准分子激光角膜屈光手术后的对比敏感度变化[J].中国实用眼科杂志,1998,16(8):478-480. 被引量:19

共引文献8

同被引文献87

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部