瞬发γ中子活化方法在铁精矿和铝矿浆多元素介质分析实验中的应用研究 被引量:2

The application study of prompt gamma netron active nethod in iron mine and aluminium ore experiment analysis
下载PDF
导出
摘要 应用瞬发γ射线中子活化分析法,研究了多元素介质中元素间的干扰、相关性问题。实验发现,在样品颗粒度和几何条件一定的条件下,样品中某一元素特征峰面积受密度、含水量及其它元素的干扰,其中受氢( H) 峰影响最大。在定量分析元素含量时必须进行含水量、密度及元素干扰之校正,探索了最佳实验条件和可行的数据校正方法,并提供了方便直观的对话式数据分析处理软件,校正结果使标准偏差减小了0 .1 ~0 .3 。 The element disturb and interrelated problem are studied in many elements material. Experiment shows that lelment feature peak area is disturbed by density and gydrogen and other elements when sample pellet size and geometry contion are fixed. Special, the influence of hydrogen peak is great. So, the data must be proofreaded and corrected in calculating element content. We selected the best geometry condition of experiment and offerred convenient and audio-visual dialogure processing programme.
出处 《河南科学》 1999年第3期240-245,共6页 Henan Science
关键词 铁精矿 铝矿浆 定量分析 多元素介质 PGNAA prompt gamma netron active analysis iron mine aluminium ore
  • 相关文献

同被引文献23

  • 1张锋,张高龙.精矿矿浆中子活化在线分析[J].同位素,2002,15(z1):68-70. 被引量:2
  • 2张兰芝,倪邦发,田伟之,王平生,黄东辉,刘存兄,张贵英,刘立坤.瞬发γ中子活化分析系统的建立[J].原子核物理评论,2005,22(1):103-105. 被引量:9
  • 3张兰芝,倪邦发,田伟之,黄东辉,张桂英,刘存兄,王平生,刘立坤,李德红.瞬发γ射线中子活化分析的现状与发展[J].原子能科学技术,2005,39(3):282-288. 被引量:33
  • 4丁大钊,叶春堂,赵志祥,等.中子物理学[M].北京:原子能出版社,2005:578-579.
  • 5赵景岐.瞬发γ射线中子活化分析及其应用[J].核技术,1985,(6):52-53.
  • 6庹先国,杨剑波,穆克亮,等.在线中子活化分析系统中样品参数变化对瞬发γ产额影响的蒙特卡罗研究[Z].中国四川绵阳:2009:873-876.
  • 7吴松茂,茅云,宋玲根,等.中子活化瞬发γ射线元素分析技术初探[J].核技术,1985,(6):27-27.
  • 8A. A. N. A Monte Carlo comparison of PGNAA sys- tem performance using 252Cf neutrons, 2. 8 - MeV neutrons and 14- MeV neutrons[J]. Nuclear Instru-ments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment,2003, 511(3) : 400-407.
  • 9Naqvi A A, Nagadi M M, Khateeb - Ur - Rehman, et al. Monte Carlo simulations for design of the KFUPM PGNAA facility [ J ]. Radiation Physics and Chernistry,2003, 66(2) : 89 -98.
  • 10Naqvi A A, Abdelmonem M S, A1- Misned G, et al. New source - moderator geometry to improve per- fonnance of 252Cf and 241Am - Be source - based PGNAA setups [ J ]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spec- trometers, Detectors and Associated Equipment,2006, 562(1) : 358 -364.

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部