期刊文献+

制氢装置中变水冷系统不锈钢件失效分析 被引量:2

FAILURE ANALYSIS OF STAINLESS STEEL PARTS IN VARIABLE WATERCOOLED HYDROGEN PLANT
下载PDF
导出
摘要 通过对制氢装置中变水冷却系统工艺条件、奥氏体不锈钢失效件服役介质的检测,并对失效件进行宏观、硬度测试、金相和电镜扫描检查,分析其服役的工作环境、条件和失效的状况,及其失效的原因,提出了防止此类部位不锈钢件失效防护措施。 In this paper,the process conditions and service medium of the austenitic stainless steel failure parts in the variable water—cooled hydrogen plant are tested.And macroscopic examination, hardness test,metallographic structure and SEM are carried out to check the failure parts in order to analyze the working environment and conditions,failure status and reasons of the failure parts.And preventive measures are put forward to prevent such failure of the stainless steel parts.
出处 《石油化工设备技术》 CAS 2011年第2期48-50,6,共3页 Petrochemical Equipment Technology
关键词 制氢装置 中变系统 法兰 弯头 失效 Hydrogen plant Medium temperature shift cooling system Flange Elbow Failure
  • 相关文献

参考文献4

二级参考文献60

共引文献32

同被引文献5

  • 1王金富.制氢装置管道材料的选用[J].石油化工腐蚀与防护,2004,21(3):19-22. 被引量:20
  • 2SH3408-1996,钢制对焊无缝管件[S].
  • 3周本省.腐蚀与防腐[M].1990,119-124.
  • 4陈涛.制氢装置中变气管线异径管(DN150/DN250)开裂理化分析报告[R].合肥通用机械研究所压力容器检验站,2010.
  • 5中国腐蚀与防护学会编.金属腐蚀手册[M].上海:上海科学技术出版社,1987.370-371.

引证文献2