期刊文献+

活性碳纤维的电吸附性能 被引量:8

Electrosorption Performance of Activated Carbon Fibers(ACF)
下载PDF
导出
摘要 研究了活性碳纤维(ACF)表面结构、性质与其电吸附性能的相关性,并应用于有机污染物的电吸附去除.结果表明:对于S_(BET)分别为791,1 003,1 314 m^2/g的ACF虽然具有相似的孔径分布范围、相近的等电点和相同的表面微观结构,但S_(BET)和微孔体积数的不同将导致ACF物理电阻值和表面电化学阻抗差异较大,从而造成ACF对有机物苯酚的电吸附效果明显不同.而且,ACF的电吸附性能受到吸附质的性质、初始浓度和介质pH值的显著影响. The correlation of the surface structure and characteristics with the electrosorption performance of ACF was studied,and it was used for removing organic pollutants by electrosorption method.The results show that the ACFs with different BET values of 791,1 003,1 314 m^2/g have the similar range of average pore diameter,isoelectric point and the same surface microstructure.However,the different BET values and micropore volumes can cause quite differences in physical resistivity and electrochemical reaction resistance of ACF.The electrosorptive performance of the same ACF is affected by the characteristics of adsorbate,its initial concentration and pH value of medium.
机构地区 同济大学化学系
出处 《建筑材料学报》 EI CAS CSCD 北大核心 2011年第1期140-144,共5页 Journal of Building Materials
基金 国家高科技发展计划(863计划)项目(2008AA06Z329) 国家自然科学基金资助项目(20877058) 上海市纳米基金资助项目(0852nm01200)
关键词 活性碳纤维 比表面积 电吸附 苯酚 activated carbon fiber specific surface area electrosorption phenol
  • 相关文献

参考文献8

二级参考文献21

  • 1戚豹,康文梅,陈年和.碳纤维加固梁二次受力性能的研究[J].河北理工学院学报,2004,26(1):144-149. 被引量:3
  • 2熊永华,陈思作.碳纤维加固混凝土结构技术计算及应用[J].工程抗震与加固改造,2005,27(1):63-65. 被引量:9
  • 3刘数华,李小进.矿物掺合料对高强混凝土抗裂性能的影响[J].新型建筑材料,2006,33(12):7-9. 被引量:6
  • 4Sherif Yehia, Christopher Y Tuan, David Ferdon, et al. Conductive Concrete Overlay/or Bridge Deck Deicing: Mixture Proportioning, Optimization, and Properties. ACI Materials Journal[ J ]. 2000, (2) : 172 - 181.
  • 5Sihai Wen, D. D. L. Chung. Carbon Fiber-Reinforced Cement as a thermistor[J ]. Cement and Concrete Research, 1999, 29(6) :961 - 965.
  • 6唐祖全.碳纤维机敏混凝土路面结构融雪化冰性能研究[C].,2002.41-45.
  • 7唐祖全.碳纤维机敏混凝土路面结构融雪化冰性能研究.2002,:41-45.
  • 8Sherif Yehia, Christopher Y Tuan, David Ferdon, et al. Conductive Concrete Overlay for Bridge Deck Deicing: Mixture Proportioning, Optimization, and Properties. ACI Materials Journal[ J]. 2000, (2): 172 -181.
  • 9Sihai Wen, D. D. L. Chung. Carbon Fiber-Reinforced Cement as a thermistor[J]. Cement and Concrete Research, 1999, 29(6):961 - 965.
  • 10Thanasis C,Triantafillou,Nikola Deskovic.Innovative prestressing with FRP sheets:Mechanics of short-term behavior[J].Journal of Engineering Mechanics,1991,117(7):1652~1672.

共引文献32

同被引文献107

引证文献8

二级引证文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部