期刊文献+

动脉压力波形分析在麻醉监测中的应用进展 被引量:1

下载PDF
导出
摘要 血流动力学监测是术中麻醉监测的重要内容之一,是麻醉医生及时了解患者情况、评估麻醉效果、调整治疗方案的重要依据。合理选择监测指标可以使医生对患者病情、疗效作出迅速、准确的判断从而有利于临床治疗及患者预后。在复杂手术或患者有明显的病理生理异常时,
作者 沈文振 岳云
出处 《医学研究杂志》 2011年第3期132-135,共4页 Journal of Medical Research
  • 相关文献

参考文献24

  • 1Huang L, Elsharydah A, Nawabi A, et al. Entrapment of pulmonary artery catheter in a suture at the inferior vena eava cannulationite [ J ]. Clin Anesth, 2004, 16 (7) : 557 -559.
  • 2Shah MR, HasselbIad V, Stevenson Lw, et al. Impact of the pulmonary artery catheter in critically ill patients:recta - analysis of randomized clinical trials [ J]. JAMA,2005,294(13) : 1664 -1670.
  • 3Harvey S, Harrison DA, singer M, et al. Assessment of the Clinical effectiveness of pulmonary artery catheters in management of patients in intensive care: a randomised controlled trial [ J ]. Lancet, 2005, 366(94) : 472 -477.
  • 4Zimmermann A,Kufner C, Hofbauer S, et al. The Accuracy of the Yigileo/FloTrae Continuous Cardiac Output Monitor. Cardiothorae Vasc Anesth[J]. 2008, 22(3): 288-293.
  • 5Manecke GR, Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration[J]. Cardiothorac Vasc Anesth,2007, 21 (1): 3 - 7.
  • 6Shahrzad B, Spiegelenberg S, et al. Cardiac Output Measured by a New Arterial Pressure Waveform Analysis Method Without CalibrationCompared With Thermodilution After Cardiac Surgery[J]. Cardiothorac Vasc Anesth,2007, 21(5) : 632-635.
  • 7MehtaY, Chand RK, Sawhney R, et al. Cardiac Output Monitoring: Comparison of a New Arterial Pressure Waveform Analysis to the Bolus Thermodilution Technique in Patients Undergoing Off - Pump Coronary Artery Bypass Surgery[J]. Cardiothorac Vasc Anesth, 2008, 22 (3) : 394-399.
  • 8McGee WT, Horswell JL, Caldenm J. et al. Validation of a continuous cardiac output measurement using arterial pressure waveforms[J]. Critical Care, 2005, 11 (5) : 24 - 25.
  • 9Vetrugno L, Costa MG, Spagnesi L, et al. Uncalibrated Arterial Pulse Cardiac Output Measurements in Patients With moderately Abnormal Left Ventricular Function [ J]. Cardiothorac VascAnesth, 2010, 21 (5) : 636-643.
  • 10Jeong YB, Kim TH, Roh YJ. Comparison of uncalibrated arterial pressure waveform analysis with continuous thermodilution cardiac output measurements in patients undergoing elective off - pump coronary artery bypass surgery[ J] . Cardiothorac VascAnesth,2010, 24 (5) : 767 - 771.

二级参考文献29

  • 1陈卉.Bland-Altman分析在临床测量方法一致性评价中的应用[J].中国卫生统计,2007,24(3):308-309. 被引量:217
  • 2Bland J M,Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement[J]. Lancet, 1986,1 : 307-310.
  • 3Bland J M, Altman D G. Measuring agreement in method comparison studies[J]. Stat Methods Med Res, 1999,8: 135-160.
  • 4Manecke G R Jr, Auger W R. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require ealibration[J]. J Cardiothorac Vasc Anesth,2007,21 :3-7.
  • 5McGee W T, Horswell J L, Calderon J,Janvier G, Van Severen T, Van den Berghe G, et al. Validation of a continuous, arterial pressure-based cardiac output measurement : a multieenter, prospective clinical trial[J]. Crit Care, 2007,11 : R105.
  • 6Manecke G R. Edwards FloTrac sensor and Vigileo monitor: easy,accurate,reliable cardiac output assessment using the arterial pulse wave[J].Expert Rev Med Devices, 2005,2: 523-527.
  • 7Lopes M C,de Cleva R,Zilberstein B,Gama-Rodrigues J J. Pulmonary artery catheter complications: report on a case of a knot accident and literature review[J]. Rev Hosp Clin Fac Med Sao Paulo, 2004,59 : 77-85.
  • 8Frazier S K, Skinner G J. Pulmonary artery catheters: state of the controversy[J]. J Cardiovasc Nurs, 2008,23 : 113-121.
  • 9Bianchini R, Melina G, Benedetto U, Rossi M, Fiorani B, Iasenzaniro M,et al. Extracorporeal membrane oxygenation for Swan Ganz induced intraoperative hemorrhage[J]. Ann Thorac Surg, 2007,83 : 2213-2214.
  • 10Reuter D A,Kirchner A,Felbinger T W,Weis F C,Kilger E, Lamm P, et al. Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function[J].Crit Care Med, 2003,31 : 1399-1404.

共引文献17

同被引文献12

引证文献1

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部