期刊文献+

Image quality of cone beam CT on respiratory motion

Image quality of cone beam CT on respiratory motion
下载PDF
导出
摘要 In this study,the influence of respiratory motion on Cone Beam CT (CBCT) image quality was investigated by a motion simulating platform,an image quality phantom,and a kV X-ray CBCT.A total of 21 motion states in the superior-inferior direction and the anterior-posterior direction,separately or together,was simulated by considering different respiration amplitudes,periods and hysteresis.The influence of motion on CBCT image quality was evaluated with the quality indexes of low contrast visibility,geometric accuracy,spatial resolution and uniformity of CT values.The results showed that the quality indexes were affected by the motion more prominently in AP direction than in SI direction,and the image quality was affected by the respiration amplitude more prominently than the respiration period and the hysteresis.The CBCT image quality and its characteristics influenced by the respiration motion,and may be exploited in finding solutions. In this study, the influence of respiratory motion on Cone Beam .CT (CBCT) image quality was investigated by a motion simulating platform, an image quality phantom, and a kV X-ray CBCT. A total of 21 motion states in the superior-inferior direction and the anterior-posterior direction, separately or together, was simulated by considering different respiration amplitudes, periods and hysteresis. The influence of motion on CBCT image quality was evaluated with the quality indexes of low contrast visibility, geometric accuracy, spatial resolution and uniformity of CT values. The results showed that the quality indexes were affected by the motion more prominently in AP direction than in SI direction, and the image quality was affected by the respiration amplitude more prominently than the respiration period and the hysteresis. The CBCT image quality and its characteristics influenced by the respiration motion, and may be exploited in finding solutions.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2011年第2期111-117,共7页 核技术(英文)
基金 Supported by National Natural Science Foundation of China(Grant No.10975187)and clinic research grant(No.LC2009B34)from the Cancer Institute
关键词 呼吸运动 图像质量 锥束CT 模拟平台 质量指标 空间分辨率 运动状态 低对比度 Respiratory motion, Cone beam CT, Image quality
  • 相关文献

参考文献10

  • 1Letourneau D, Martinez A A, Lockman D, et al. Int J Radiat Oncol Biol Phys, 2005, 62: 1239-1246.
  • 2White E A, Cho J, Vallis K A, et al. Int J Radiat Oncol Biol Phys, 2007, 68: 547-554.
  • 3Borst G R, Sonke J J, Betgen A, et al. Int J Radiat Oncol Biol Phys, 2007, 68: 555-561.
  • 4Oelfke U, Tricking T, Nill S, et al. Med Dosim, 2006, 31: 62-70.
  • 5Chen J, Morin O, Aubin M, et al. Br J Radiol, 2006, 79S1:87-98.
  • 6Burridge N, Amer A, Marchant T, et al. Int J Radiat Oncol Biol Phys, 2006,66:892-897.
  • 7Song J Y, Nam T K, Ahn S J, et al. Med Dosim, 2009, 34: 117-125.
  • 8Lujan A E, Larsen E W, Baiter J M, et al. Med Phys, 1999, 26:715-720.
  • 9George R, Vedam S S, Chung T D, et al. Med Phys, 2005, 32: 2850-2861.
  • 10Shirato H, Seppenwoolde Y, Kitamura K, et al. Semin Radiat Oncol, 2004, 14: 10-18.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部