摘要 Severe tricuspid regurgitation with permanent pacemaker wire passing through the orifice of bioprosthetic tricuspid valve is extremely rare. We present a case of such kind of patient and redid bioprosthetic tricuspid valve replacement. A hawk mouth forceps for bone surgery was used to cut off the mental ring of ruined bioprosthetic tricuspid valve and the ruined valve was removed. A new bioprosthetic tricuspid valve was implanted and the wire of permanent pacemaker was left outside the ring of bioprosthetic tricuspid valve. This method may be helpful for such kind of patient. Severe tricuspid regurgitation with permanent pacemaker wire passing through the orifice of bioprosthetic tricuspid valve is extremely rare. We present a case of such kind of patient and redid bioprosthetic tricuspid valve replacement. A hawk mouth forceps for bone surgery was used to cut off the mental ring of ruined bioprosthetic tricuspid valve and the ruined valve was removed. A new bioprosthetic tricuspid valve was implanted and the wire of permanent pacemaker was left outside the ring of bioprosthetic tricuspid valve. This method may be helpful for such kind of patient.
机构地区 Department of Surgery
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第6期958-960,共3页 中华医学杂志(英文版)
关键词 tricuspid valve replacement bioprosthetic valve complete atrioventricular block REOPERATION tricuspid valve replacement bioprosthetic valve complete atrioventricular block reoperation
  • 相关文献

参考文献15

  • 1Filsoufi E Anyanwu AC, Salzberg SP, Frankel T, Cohn LH, Adams DH. Long-term outcomes of tricuspid valve replacement in the current era. Ann Thorac Surg 2005; 80: 845-850.
  • 2Cartier M, Hrbert Y, Pellerin M, Bouchard D, Perrault LP, Cartier R, et al. Tricuspid valve replacement: an analysis of 25 years of experience at a single center. Ann Thorac Surg 2003; 75: 47-50.
  • 3Iscan ZH, Vural KM, Bahar I, Mavioglu L, Saritas A. What to expect after tricuspid valve replacement? Long-term results. Eur J Cardiothorac Surg 2007; 32: 296-300.
  • 4Kunadian B, Vijayalakshmi K, Balasubramanian S, Dunning J Should the tricuspid valve be replaced with a mechanical or biological valve? Interac Cardiovasc Thorac Surg 2007; 6: 551-557.
  • 5Rizzoli G, Vendramin I, Nesseris G Bottio T, Guglielmi C, Schiavon L. Biological or mechanical prosthesis in tricuspid position? A meta-analysis of intra-institutional results. Ann Thorac Surg 2004; 77: 1607-1614.
  • 6Guenther T, Noebauer C, Mazzitelli D, Busch R, Tassani-Prell P, Lange R. Tricuspid valve surgery: a thirty-year assessment of early and late outcome. Eur J Cardiothorac Surg 2008; 34: 402-409.
  • 7Do QB, Pellerin M, Carrier M, Cartier R, H6bert Y, Pag6 P, et al. Clinical outcome after isolated tricuspid valve replacement:20-year experience. Can J Cardiol 2000; 16: 489-493.
  • 8Ratnatunga CP, Edwards MB, Dore CJ, Taylor KM. Tricuspid valve replacement: UK Heart Valve Registry mid-term results comparing mechanical and biological prostheses. Ann Thorac Surg 1998; 66: 1940-1947.
  • 9Merin O, Ilan M, Oren A, Fink D, Deeb M, Bitran D, et al. Permanent pacemaker implantation following cardiac surgery: indications and long-term follow-up. Pacing Clin Electrophysiol 2009; 32: 7-12.
  • 10Jokinen J J, Turpeinen AK, Pitkiinen O, Hippelainen M J, Hartikainen JE. Pacemaker therapy after tricuspid valve operations: implications on mortality, morbidity, and quality of life. Ann Thorac Sure 2009: 87: 1806-1814.