大同第二发电厂两台200MW空冷机组实际运行情况表明,空冷机组比同类型湿冷机组煤耗相对要高,经全面系统的分析与研究,其原因主要是环境温度、大风、防冻、运行方式等的影响,并以此提出了相应的降耗措施。
Abstract Operation of two dry cooling units in Datong Power plant shown that the coal consumption of these units was relatively higher than that of the simi lar wet cooling units.Based on a systematic analysis and study,it was found that the higher coal consumption was mainly caused by ambient tempera ture,wind,freezing and operation mode.
出处
《热力发电》
CAS
北大核心
1999年第4期16-18,共3页
Thermal Power Generation