摘要
介绍了某电厂1000MW直流塔式超超临界锅炉T23钢水冷壁裂纹的类型及泄漏部位的结构,分析了裂纹产生原因,提出了有效的解决方案。
The type of the cracks of water wall,the material of which is T23 steel,in 1000MW ultra-supercritical tower-type once-through boiler in a power plant was introduced;and the structure of leakage fault position was described.The reasons of the cracks were analyzed;and effective solution was put forward.
出处
《华电技术》
CAS
2011年第4期44-46,77,共3页
HUADIAN TECHNOLOGY
关键词
直流锅炉
水冷壁
裂纹
原因分析
处理措施
once-through boiler
water wall
crack
reason analysis
treatment measure