摘要 针对JPEG和DICOM两种格式活体人头颅的CT图像,采用自编Matlab程序对前额骨、顶骨和枕骨厚度以及头宽、头长、头围和颅围等颅骨几何特征进行大批量精确测量.对测量结果进行的正态性检验表明:颅骨几何特征不服从正态分布;Kruskal-Wallis单因素方差分析的结果表明:不同格式CT图像对前额骨、顶骨和枕骨厚度有显著影响,对头宽、头长、头围和颅围无显著影响. The geometric characteristics of the alive human skull(the thickness of the frontal,parietal and occipital bones,head width,head length,head circumference and skull circumference) were measured accurately by self-compiled Matlab program in this study.The results of the normality test show that the measurement results do not obey normal distribution;Kruskal-Wallis one-way ANOVA analysis show that CT images of different formats have a significant effect on the thickness of the frontal,parietal and occipital bones,and have no significant effects on the other geometric characteristics.
出处 《小型微型计算机系统》 CSCD 北大核心 2011年第5期968-971,共4页 Journal of Chinese Computer Systems
基金 天津市应用基础及前沿技术研究计划重点项目(08JCZDJC15000)资助
关键词 颅骨 CT图像 测量 MATLAB DICOM human skull CT image measurement matlab DICOM
  • 相关文献

参考文献5

二级参考文献20

  • 1吕庆文,李树祥.CT图像中大脑边界的提取与跟踪及其算法实现[J].北京生物医学工程,1995,14(2):111-113. 被引量:6
  • 2徐萃薇 孙绳武.计算方法引论[M].北京:高等教育出版社,2002..
  • 3Gerald Recktenwald.数值方法和MATLAB实现与应用[M].北京:机械工业出版社,2004..
  • 4TANG H,WUA E X.MRI brain image segmentation by multi-resolution edge detection and region selection[J].Computerized Medical Imaging and Graphics,2000,24:349-357.
  • 5Tang H,Wua EX.MRI brain image segmentation by multi-resolution edge detection and region selection.Computerized Medical Imaging and Graphics,20002;4:349
  • 6Cotton F,Vallee B.Cranial sutures and craniometric points detected on MRI.Surg Radiol Anat,2005;27:64
  • 7Nagashimal M,Inouel K.Three-dimensional imaging and osteometry of adult human skulls using helicalcomputed tomography.Radiologic anatomy,1998;20:291
  • 8Ruan Jesse, Prasad P. The effects of skull thickness variations on human head dynamic impact responses [ A ]. In : Proc. 45th Stapp Car Crash Conf, 2001[C]. USA: SAE, 2001. Paper No. 01S- 03.
  • 9Hakim S, Watkin KL, Elahi MM, et al. Measurement of cranial bone thickness using A-mode ultrasound [ A ]. In: 19th International Conference IEEE/EMBS [ C ]. Chicago, USA: IEEE, 1997. 613- 616.
  • 10Hertel G, Hirschfelder H. In vivo and in vitro CT analysis of the occipital [J] . Eur Spine J, 1999, 8: 27- 33.

共引文献140

同被引文献8

  • 1Nagarajan MB, Coan P, Huber MB, eta[. Computer-aided diag nosis for phase-contrast X-ray computed tomography: Quantita tive characterization of human patellar cartilage with high-dimen sional geometric features. J Digit Imaging, 2014,27(1):98-107.
  • 2Mehl J, Matthias JF, Bode G, et al. Association between patellar cartilage defects and patellofemoral geometry: A matched-pair MRI comparison o{ patients with and without isolated patellar car- tilage defects. [-2015-03-011. http://link, springer, eom/article/ 10. 1007/s00167-014-3385-7/fulltext. html.
  • 3Cachier P, Mangin JF, Pennec X, et al. Multisubject non-rigid registration of brain MRI using intensity and geometric features // Niessen WJ, Viergever MA. MICCAI 2001. IANCS. Springer, Heidelber: 2001. 2015-03-01. tttp://link, springer, corn/chap ter/10. 1007/3 540 45468-3_88#.
  • 4Zhao QY, Pizer S, Niethammer M, et al. Geometric-fealure- based spectral graph matching in pharyngeal surface registration. Med Image Comput Comput Assist Interv, 2014, 17 (Pt 1): 259-266.
  • 5Gupta A, Verma HK, Gupta S. A hybrid framework/or registra- tion of carotid ultrasound images combining iconic and geometric features. Med Biol Eng Comput, 2013,51 (9) : 1043 1050.
  • 6Rusk6 L, Perfinyi A. Automated liver lesion detection in CT ima- ges based on multi level geometric features. Int J Comput Assist Radiol Surg, 2014,9(4):577 593.
  • 7Cben X, Zbeng YP, Guo JY, et al. Sonomyographic responses during voluntary isometric ramp contraction of the human rectus femoris muscle. EurJ ApplPhysiol, 2012,112(7) :2603 2614.
  • 8Potocknik B, Cigale B, Zazula D. Computerized detection and recognition of follicles in ovarian ultrasound images: A review. Med Biol Eng Comput, 2012,50(12):1201 1212.

引证文献1

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部