通过建立冷凝器的数学模型、设计算法并运用Lab View图形化编程进行冷凝器稳态仿真,计算结果同相关实验数据相比最大误差为8.38%,获得较为合理的仿真结果,为今后采用该软件对空调系统及其它部件做更进一步的研究提供了参考依据。
A mathematical model of condenser was established,algorithm was presented and Lab View graphical programming for steady-state simulation of condenser was applied in this paper.Comparing with related experimental data,the maximum error was 8.38% and a quite reasonable calculation result was obtained.This try will provide a reference for the further research of air conditioning systems and other components using the Lab View.