期刊文献+

间隔部旁道射频消融发生房室传导阻滞的临床分析 被引量:2

Retrospective analysis of atrioventricular block triggered by radiofrequency ablation in the treatment of septal accessory pathway
下载PDF
导出
摘要 目的:探讨间隔部房室旁道射频消融术发生房室传导阻滞的原因。方法:回顾分析67例间隔部旁路参与的房室折返性心动过速患者射频消融的临床资料。结果:消融成功率为98.5%(66/67),3例发生Ⅱ度至Ⅲ度房室传导阻滞,发生率为4.55%(3/66)。结论:虽然房室旁路的消融手术成功率高、操作安全,但间隔部旁路消融仍具有挑战性。熟练的心电生理和解剖知识、精确标测、低功率放电、增加消融电极稳定性,有助于减少房室传导阻滞的发生。 Objective:To investigate the cause of atrioventricular block(AVB) triggered by radiofrequency ablation(RFCA) in the treatment of septal accessory pathway.Methods:We retrospectively analyzed the clinic features of patients who were cured by RFCA with septal accessory pathway.Results:The success rate for ablation of septal accessory pathway was 98.5%(66/67).AVB occurred in 3 of 66 patients(4.55%) of second-degree block to third-degree block.Conclusion:Although ablation of accessory bypass tracts is a successful and safe procedure,septal pathways bypass remains challenging.Accurate knowledge of cardiac electrophysiology and anatomy involved,precise mapping,lower ablation energy,enhanced catheter stability may reduce AVB.
出处 《现代医学》 2011年第2期146-148,共3页 Modern Medical Journal
关键词 射频导管消融 间隔部旁路 房室传导阻滞 radiofrequency catheter ablation septal accessory pathway atrioventricular block
  • 相关文献

参考文献11

  • 1射频导管消融治疗快速心律失常指南(修订版)[J].中国心脏起搏与心电生理杂志,2002,16(2):81-95. 被引量:222
  • 2郭继鸿,刘峰.心律失常的射频消融治疗[M].北京:北京大学医学出版社,2004:88.
  • 3中国生物医学工程学会心脏起搏与电生理分会射频消融学组 中国心脏起搏与电生理杂志编辑部.射频电流导管消融治疗快速心律失常指南[J].中国心脏起搏与电生理杂志,1996,10:113-113.
  • 4KIMMAN G P,TOROK T S,THEUNS D A,et al.Comparison of radiofrequency versus cryothermy catheter ablation of septal accessory pathways[J].Heart,2003,89:1091-1092.
  • 5FITZPATRIC A P,GONZALES R P,LESH M D,et al.New algorithm for the localization of accessory atrioventricular connections using a baseline electrocardiogram[J].J Am Coll Catdiol,1994,23:107.
  • 6胡大一,杨新春.间隔部房室旁道的射频消融[J].中国心脏起搏与心电生理杂志,1996,10(4):171-172. 被引量:9
  • 7CALKINS H,LANGBERG J,SOUSA J,et al.Radiofrequency catheter ablation of accessory atrioventricular connections in 250 patients[J].Circulation,1992,85:1337-1346.
  • 8PAULA G M,SANDEEP M P,SUSAN E B,et al.Septal accessory pathway:anatomy,causes for difficulty,and an approach to ablation[J].Indian Pacing Electrophysiol J,2010,10(7):292-309.
  • 9MICHAEL S S,MICHAEL J S,BERTRAND A R,et al.Inadvertent atrioventricular block during radiofrequency catheter ablation[J].Circulation,1996,94:3214-3220.
  • 10PECHT B,MAGINOT K R,BORAMANAND N K,et al.Techniques to avoid atrioventricular block during radiofrequency catheter ablation of septal tachycardia substrates in young patients[J].J Interv Card Electrophysiol,2002,7(1):83-88.