期刊文献+

标准检查条件下非心脏病心脏标准摄取值与组织CT值的相关性 被引量:2

Relativity between tissue standard uptake value and self CT value under standard examination condition in heart without diseases
下载PDF
导出
摘要 目的探讨标准检查条件下非心脏病患者心脏18F-FDG PET显像标准摄取值(SUV)是否受组织CT值的影响。方法在我院接受PET/CT检查的患者中随机抽取88例,排除心脏疾病,设立高血压组、贫血组、肿瘤组、正常组4个组,每组22例,观察不同机体状态下心脏组织SUV和CT值,测量左心室侧壁肌、室间隔肌、左心室腔的SUV和CT值,分析各组左心室侧壁肌、室间隔肌、左心室腔CT值和SUV的组间差异,进一步分析各组内不同组织SUV与自身CT值的相关性。结果贫血组左心室侧壁肌、室间隔肌、左心室腔CT值低于高血压组、肿瘤组和正常组(P<0.05),而各组间SUV差异无统计学意义(P>0.05);各组内左心室侧壁肌、室间隔肌、左心室腔SUV与其身CT值无相关性(P>0.05)。结论标准检查条件下非心脏病患者心脏组织18F-FDG PET显像SUV与组织CT值无相关性,SUV相对稳定。 Objective To observe whether the heart's 18F-FDG PET standard uptake value(SUV) be influenced by tissue CT value under standard examination condition in subjects without heart disease.Methods Totally 88 cases without heart diseases undergoing 18F-FDG PET of heart were randomly selected and divided into hypertension group,anemia group,cancer group and normal group(each n=22).SUV and CT value of left ventricle lateral wall muscle,interventricular septum muscle and left ventricle cavity were measured and statistically analyzed among 4 groups,and further investigations of the relativity between SUV and self CT value of the above structures were performed.Results In anemia group,CT values of left ventricle lateral wall,interventricular septum muscle and left ventricle cavity were lower than those of the other 3 groups(P0.05).There was no significant difference of SUV of above structures among 4 groups(P0.05),nor relativity between SUV and self CT value of above structures inside every group(P0.05).Conclusion Under standard examination condition,there is no relativity between tissue SUV and self CT value of heart without diseases,indicating that SUV is relatively stable for certain heart tissue.
出处 《中国医学影像技术》 CSCD 北大核心 2011年第4期723-726,共4页 Chinese Journal of Medical Imaging Technology
关键词 心脏 正电子发射型体层摄影术 标准摄取值 影响因素 Heart Positron-emission tomography Standard uptake value Influence factor
  • 相关文献

参考文献4

  • 1Bonta DV, Wahl RL. Overcorreetion of iodinated contrast atten- uation in SPECT-CT: phantom studies. Med Phys, 2010, 37 (9) : 4897-4901.
  • 2Kaneta T, Hakamatsuka T, Takanami K, et al. Evaluation of the relationship between physiological FDG uptake in the heart and age, blood glucose level, fasting period, and hospitalization. Ann Nucl Med, 2006,20(3) :203-208.
  • 3施一平,黄钢,万良荣,孙晓光,刘建军,陈虞梅.^(18)F-FDGPET/CT显像在正常人各器官的SUV与CT值分布[J].上海第二医科大学学报,2005,25(12):1250-1252. 被引量:7
  • 4缪蔚冰,李瑞珍,陈少明,彭接权,吴晶.^(18)F-FDG全身显像中心肌摄取的变化[J].中国医学影像技术,2010,26(10):1950-1952. 被引量:2

二级参考文献20

  • 1Gayed IW,Liu HH,Wei X,et al.Patterns of cardiac perfusion abnormalities after chemoradiotherapy in patients with lung cancer.J Thorac Oncol,2009,4(2):179-184.
  • 2Zophel K,Holzel C,Dawel M,et al.PET/CT demonstrates increased myocardial FDG uptake following irradiation therapy.Eur J Nucl Med Imaging,2007,34(6):1322-1323.
  • 3Israel O,Weiler-Sagie M,Rispler S,et al.PET/CT quantitation of the effect of patient-related factors on cardiac 18F-FDG uptake.J Nucl Med,2007,48(2):234-239.
  • 4Williams G,Kolodny GM.Suppression of myocardial 18F-FDG uptake by preparing patients with a high-fat,low carbohydrate diet.AJR Am J Roentgenol,2008,190(2):W151-W156.
  • 5Khandani AH,Isasi CR,Blaufox MD.Intra-individual variability of cardiac uptake on serial whole-body 18F-FDG PET.Nucl Med Commun,2005,26(9):787-791.
  • 6Groot MD,Meeuwis APW,Kok PJM,et al.Influence of blood glucose level,age and fasting period on non-pathological FDG uptake in heart and gut.Eur J Nucl Med Mol Imaging,2005,32(1):98-101.
  • 7Kaneta T,Hakamatsuka T,Takanami K,et al.Evaluation of the relation between physiological FDG uptake in the heart and age,blood glucose level,fasting period,and hospitalization.Ann Nucl Med,2006,20(3):203-208.
  • 8Kates AM,Herrero P,Dence C,et al.Impact of aging on substrate metabolism by the human heart.J Am Coll Cardiol,2003,41(2):293-299.
  • 9Yamanouchi M,Yoshida K,Niwayama H,et al.Effect of the duration of fasting on myocardial Fluorine-18-Deoxyglucose positron emission tomography images in normal males.Jpn Circ J,1996,60(6):319-327.
  • 10李果珍.临床CT诊断学[M].人民卫生出版社,2002,5.524.

共引文献7

同被引文献20

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部