期刊文献+

钢管中频加热温度的红外测量 被引量:2

Infrared Method for Testing the Mid-frequency Heating Temperature of Steel Pipes
下载PDF
导出
摘要 介绍了一种非接触式钢管中频加热温度的测量方法,与直接接触式测量方法进行了对比,讨论了影响非接触式钢管中频加热温度的测量方法准确性的因素。结果表明,非接触式钢管中频加热温度的测量方法具有更高的准确性,与接触式测温配合使用、互为补充,增强了测温的可靠性。 In the steel pipes coating processing, direct-touching and un-touching are two methods in testing the steel pipes' temperature. And presently the direcvtouching method is mainly used, which is performed by using a tempilstick to get the surface temperature of steel pipes after mid frequency heating. The two methods have their advantages and disadvantages respectively. In this paper, a kind of infrared testing method is introduced and compared with the direct-touching method. The impact factors in testing temperature are discussed. The application results show that this kind of un-touching method can give much more true and precise temperature values of the steel pipes.
出处 《腐蚀与防护》 CAS 北大核心 2011年第5期406-408,共3页 Corrosion & Protection
关键词 管道防腐 温度控制 温度测量 测温笔 红外测温 pipeline corrosion protection temperature control temperature testing tempilstick infrared testing temperature
  • 相关文献

参考文献2

二级参考文献15

  • 1徐金卿.红外物理与技术[M].西安:西安电子科技大学出版社,1989.310-314.
  • 2周书栓.红外辐射测量基础[M].上海:上海交通大学出版社,1991..
  • 3服部晋 位田敏和 等.简易辐射温度计[J].日本赤外线学会志,1996,6(2):21-27.
  • 4安藤哲男 大沼修.新式双色温度计[J].红外,1988,(10):36-38.
  • 5王伯雄 马秉林.微机控制的红外测温技术[J].微电子学与计算机,1986,3(4):26-28.
  • 6崔志尚,温度计量与测试,1998年,140页
  • 7徐南荣,红外辐射与制导,1997年,9页
  • 8陈玻若,红外系统,1995年,146页
  • 9周书栓,红外辐射测量基础,1991年
  • 10刘梅冬,压电铁电材料与器件,1990年,234页

共引文献61