摘要
目的:探讨HP4002型电脑骨创伤治疗仪治疗下肢骨折部位软组织肿胀的疗效.方法:将入院治疗的120例骨折后肢体肿胀患者随机分成A、B二组,每组60例,二组实验时间均为一周,每日一次,每次一小时,操作时二组均抬高患肢20-30度,在伤后8-10h内,A组采用可产生脉冲磁场HP4002型骨创伤治疗仪治疗;B组将β-七叶皂20mg溶于5%GS250ml静脉滴注.结果:骨创伤治疗仪治疗骨折部位软组织肿胀具有良好的效果,方便,安全可靠,无副作用.结论:骨创伤治疗仪具有明显抗渗出,消水肿等作用,治疗骨折后肢体肿胀明显优于β-七叶皂苷钠.
Objective: Discusses the HP4002 computer hone wound treatment meter treatment lower limb hone fracture spot soft tissue swelling curative effect. Methods:Will be hospitalized the treatment 120 example hone fracture hind legs body swelling patient to divide into A,the B two groups stochastieally,each group of 60 examples,two group of run times will be a week,daily one time,each time an hour,when operation two groups will raise the trouble extremity 20--30 degree,after the wound in 8--10h,A group will use may have the pulse mag- netic field HP4002 bone wound treatment meter treatment; B group beta -- seven soap 20mg will dissolve in the 5~GS250ml vein drop note. Results:The bone wound treatment meter treatment bone fracture spot soft tissue swelling has the good effect,convenient,safe reliable, does not have the side effect. Conclusion: The bone wound treatment instrument has obviously is impervious, disappears functions and so on dropsy, the treatment bone fracture hind legs body swelling obviously surpasses beta -- seven soap glucoside sodium.
出处
《按摩与康复医学》
2011年第5期19-20,共2页
Chinese Manipulation and Rehabilitation Medicine
关键词
骨创伤治疗仪
骨折
软组织肿胀
Bone wound treatment meter -Bone fracture Soft tissue swelling