针对汽轮发电机组调峰运行的要求,分析了高中压联合启动在调峰运行中存在的问题和中缸启动方法在调峰运行中的适应性。并就3种不同类型的机组,分析阐述了影响中缸启动的一些因素。
In accordance with the peak load operation mode required by the power system,the difficulties for HP-IP joint starting are discussed in this paper,,and the advantageS of IP starting for peak load operation are analyzed. Based on three type steam turbine sets, some factors affecting the IP stare considered at the same time.
出处
《华中电力》
1999年第3期14-16,共3页
Central China Electric Power
关键词
中缸启动
调峰
汽轮发电机组
Steam Turbine IP Starting Peak Load Operation