摘要
介绍了发电机在过去检修中发现的问题, 并对其进行了分析和讨论。为防止类似事故出现, 指出在发电机大修中应注意端部线圈固有频率、定子引水管及定子铁芯等的检查和应采取的措施。
This paper introduces and discusses the problems found in past maintenance works. In order to prevent similar events to occur in the overhaul,The authors point out:during the overhaul,great attention must be paid to the inspection and the correct measures of inherent frequency of end windings,stator cooling water inlet conduits and stator core,etc.
出处
《河北电力技术》
1999年第5期14-16,共3页
Hebei Electric Power
关键词
发电机
定子线圈
铁芯
大修
检查
generator stator winding resonance iron core