基于LabVIEW的载流子迁移率测试系统的设计 被引量:3

Design of measurement system for the charge carrier drift mobility based on LabVIEW
下载PDF
导出
摘要 针对传统测试方法所存在的局限性,根据线性增压载流子瞬态谱(CELIV)这一原理,以LabVIEW8.60为平台设计半导体载流子迁移率测试系统。介绍了系统的硬件、软件构成,详细介绍了软件的设计及功能实现。测试结果表明,该系统具有较好的数据采集、数据保存、显示功能与可操作性,同时软件具有参数设置灵活、可二次开发等优点。 Aiming at solving the limitations of traditional equipments and methods,this paper set up a measurement system for the charge carrier drift mobility on the basis of the theory of carrier extraction by linearly increasing voltage(CELIV),regarding LabVIEW8.60 as a platform.It describes the overall design concept of the measurement system,hardware components,software development and its functional realization.Testing result shows the system has done well in data acquisition,data storage,display function and maneuverability,furthermore,the software also has outstanding ability in parameters setting and second development.
出处 《电子测量技术》 2011年第4期70-73,共4页 Electronic Measurement Technology
关键词 LABVIEW CELIV 迁移率 测试系统 LabVIEW CELIV mobility measurement system
  • 相关文献

参考文献8

二级参考文献34

共引文献91

同被引文献24

  • 1张东风,孔德义,梅涛,陶永春.离子迁移谱仪微型化的现状与进展[J].仪器仪表学报,2006,27(2):199-204. 被引量:22
  • 2MIKHAIL P G. Method of analysis of impurities in gases : SU, 966583[P]. 1982-10-15.
  • 3BURYAKOV I A, KRYLOV E V, NAZAROV E G, et al. A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric field [ J ]. Interna- tional Journal of Mass Spectrometry and Ion Processes, 1993.3 : 143-148.
  • 4NAZAROV G E, MILLER R A, EICEMAN G A. Minia- ture differential mobility spectrometry using atmospheric pressure photoionization [ J ]. Anal. Chem. , 2006,78 : 4553-4563.
  • 5MILLER R A, EICEMAN G A, NAZAROV E G, et al. A novel weak-machined high-field asymmetric waveform- ion mobility spectrometer [ J ]. Sensors Actuators B Chem. ,2000,67(3) :300-306.
  • 6PURVES R W, GUEVREMONT R, Electrospray ioniza- tion high-field asymmetric waveform ion mobility spec- trometry mass spectrometry [ J ]. Analytical Chemistry, 2006, 71 (13) :2346-2357.
  • 7MILLER R A, EICEMAN G A, NAZAROV E G, et al. A novel weak-machined high-field asymmetric waveform- ion mobility spectrometer [ J ]. Sensors Actuators B Chem. ,2000,67 (3) :300-306.
  • 8CANTERBURY J D, GLADDEN J, BUCK L, et al. Ahigh voltage asymmetric waveform generator for FAIMS [J].J. Am. Soc. Mass Spectrom,2010,21:lll8-1121.
  • 9KRYLOV E V. Pulses of special sharps formed on a ca- pacitive load [ J ]. Instruments and Experimental Tech- niques, 1997,40 ( 5 ) : 628-631.
  • 10KRYLOV E V, COY S L, VANDERMEY J, et al. Selec- tion and generation of waveforms for differential mobility spectrometry[J]. Rev. Sei. Instrum. ,2010,81:024101.