期刊文献+

击穿耐压装置容量指标

On the capacity performance index of voltage-resisting and puncture tester
下载PDF
导出
摘要 根据影响介质击穿的主要因素,着重阐述了交流耐压击穿装置的容量指标问题。在确定耐压击穿装置的容量时,不仅要考虑到被试样件两极间的等效电容值,同时还要估计到试样在击穿过程可能产生的最大击穿电流值。对于某种绝缘材料或构件,合理选定耐压击穿装置的容量对正确进行试验是很重要的。 On the basis of primary factors influencing puncture of mediums,this paper emphatically points out the capacity performance index of voltage-resisting and puncture tester.When its capacity is defined,it would consider the equivalent capacitance of test sample between electrodes,and would estimate the highest puncture current value of test sample producing in the puncturing course.It is very important to choose retionally the capacity of voltage-resisting and puncture test for some insulating material and components.
作者 于治会
出处 《移动电源与车辆》 1999年第3期8-13,共6页 Movable Power Station & Vehicle
关键词 绝缘材料 耐压击穿装置 高电压 耐压试验 insulating material puncture of medium dielectrie itensity
  • 相关文献

参考文献2

  • 1刘耀南,邱昌容.电气绝缘测试技术[M]机械工业出版社,1981.
  • 2《电气绝缘测试技术》编写组.电气绝缘测试技术[M]上海人民出版社,1972.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...