期刊文献+

无功补偿设备对风电机组暂态特性的影响 被引量:2

Influence on Transient Characteristics of Wind Turbine by Its Reactive Compensation Equipment
下载PDF
导出
摘要 在电力系统仿真软件PSASP6.8中建立了基于静止无功补偿器(static var compensator,简称SVC)补偿型发电机组的模型,仿真计算在一个由5台风电机组构成的风电系统中进行,对采用SVC装置的异步风电机组暂态特性进行了分析。仿真结果表明SVC补偿型机组具有快速调节无功功率的能力,SVC装置对机端电压有一定的支撑能力,风电场升压变压器的低压侧装SVC,可以减轻风电机组并网过程中对系统的冲击,实现恒速风力发电机组的柔性并网。 The wind turbine model with static var compensator (SVC for shortern)was established in the power system simulation software PSASP 6.8.The wind farm with SVC was consisted of 5 wind turbines.Its steady and transient characteristics were analyzed.The results showed that the SVC had the ability to quickly adjust reactive power and reduce the impact to power grid while the wind turbine was started up realizing the flexiable combination with the power net.
机构地区 新疆大学
出处 《电机技术》 2011年第2期22-25,共4页 Electrical Machinery Technology
关键词 风电机组 风电场 静止无功补偿器 暂态特性 Wind turbine unit Wind farm Static var compensator(SVC) Transient characteristic
  • 相关文献

参考文献5

  • 1王纯绮,晁勤.达坂城无功补偿分析[D].乌鲁木齐:新疆大学,2006.
  • 2范高锋,王纯琦,乔元,赵海翔,薛锋,王伟胜.SVC补偿型定速风电机组模型及其特性分析[J].电网技术,2007,31(22):64-68. 被引量:20
  • 3陈树勇.大型并网风力发电场规划方法研究.博士论文.中国电力科学研究院.
  • 4Wu Xueguang, et al. Application of models of the wind energy conversion system to wind power dynamic analysis, Power System Technology, 1998. Proceedings. POWERCON' 98. International Conference on, Vol.2, Aug.1998, pp: 1406-1411.
  • 5潘文霞,陈允平,沈祖诒.风电系统及其电压特性研究[J].河海大学学报(自然科学版),2001,29(1):88-92. 被引量:17

二级参考文献22

共引文献32

同被引文献20

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部