摘要 以广东电网一次调频运行管理规定为例,探讨了水电机组一次调频限幅及与自动发电控制(automatic generation control,AGC)协调规范。针对在一次调频过程中可能发生抬机的原因,指出无需限制轴流式机组的一次调频限幅,建议设定水电机组一次调频的调节范围,以避免抬机、水力振动和超出力对机组稳定运行的不利影响;列举了2种电厂常用的AGC与调速器的配合方式,指出一次调频与AGC配合的矛盾及其原因,并介绍了一次调频与AGC相互协调的实例。 This article takes administrative provisions for operation of primary frequency in Guangdong Power Grid Corporation as an example and discusses limiting of primary frequency in hydropower units and coordination norm for automatic generation control(AGC).Aiming at reasons for potential turbine lifting in the process of primary frequency,the article indicates that there is no need to restrict limiting of primary frequency of axial flow type units,it suggests to set a range of adjustment for primary frequency in avoidance of unfavorable impact of turbine lifting,hydraulic vibration and excess output on stable operation of units.The article lists two conjunctive modes between AGC and speed regulators in common use and it presents the contradiction and reasons for the conjunction;besides,it introduces examples of mutual coordination between primary frequency and AGC.
出处 《广东电力》 2011年第4期46-48,53,共4页 Guangdong Electric Power
关键词 水电机组 一次调频 限幅 自动发电控制 hydropower units primary frequency limiting AGC
  • 相关文献

参考文献9

二级参考文献8

  • 1王国秉,于步聪.水力发电厂水工建筑物首轮安全性评价综述[J].山西水利科技,2006(4):1-4. 被引量:2
  • 2叶鲁卿.适应式变参数PID微型计算机调速器[J].水电设备,1986,1.
  • 3俄罗斯生态、技术、核监督局.2009年发生在俄罗斯水力发电公司分部--萨扬·舒申斯克水电站事故原因技术报告书[R].中国大坝协会译,2009.
  • 4沈祖贻.水轮机调节[M].北京:中国水利水电出版社,1998.
  • 5华中电监局.华中区域发电厂并网运行管理规定实施细则(试行)(网上征求意见稿)[EB/OL].http://www.sere.gov.cn/opencms/export/serc/points/2008012308.010c
  • 6国家技术监督局.水轮机调速器与油压装置试验验收规程[S].北京:中国标准出版社,2004.
  • 7华北电网发电机组一次调频运行管理规定[S].2006.
  • 8华中电网发电机组一次调频技术管理规定(试行)[S].2006.

共引文献35

同被引文献10

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部