摘要 近10年多模式影像融合设备PET—CT取得成功,随之的目标便是研制PET和MR的同机融合设备MR—PET。MR是多参数、多序列成像,不但具有良好的软组织解剖分辨率,同时也可以进行功能成像,但与PET相比,MR在定量观察分子示踪方面仍有限制,敏感性也不及PET,
出处 《中华放射学杂志》 CAS CSCD 北大核心 2011年第4期412-414,共3页 Chinese Journal of Radiology
  • 相关文献

参考文献18

  • 1Wehrl HF,Judenhofer MS,Wiehr S,et al.Pre-clinical PET/MR:technological advances and new perspectives in biomedical research.Eur J Nucl Med Mol Imaging,2009,36 Suppl 1:S56 -S68.
  • 2Boss A,Bisdas S,Kolb A,et al.Hybrid PET/MRI of intracranial masses:initial experiences and comparison to PET/CT.J Nucl Med,2010,51:1198-1205.
  • 3Wehrl HF,Judenhofer MS,Thielscher A,et al.Assessment of MR compatibility of a PET insert developed for simultaneous multiparametric PET/MR imaging on an animal system operating at 7 T.Magn Reson Med,2011,65:269-279.
  • 4Shao Y,Cherry SR,Farahani K,et al.Simultaneous PET and MR imaging.Phys Med Biol,1997,42:1965-1970.
  • 5Catana C,Wu Y,Judenhofer MS,et al.Simultaneous acquisition of multislice PET and MR images:initial results with a MRcompatible PET scanner.J Nucl Med,2006,47:1968-1976.
  • 6Lucas A J,Hawkes RC,Ansorge RE,et al.Development of a combined microPET-MR system.Technol Cancer Res Treat,2006,5:337-341.
  • 7Tsoumpas C,Mackewn JE,Halsted P,et al.Simultaneous PETMR acquisition and MR-derived motion fields for correction of nonrigid motion in PET.Ann Nucl Med,2010,24:745-750.
  • 8Mackewn JE,Strul D,Charles-Edwards G,et al.Performance evaluation and MR compatibility assessment of an optical fibre based pre-clinical MR-compatible PET scanner.IEEE Nuclear Science Symposium Medical Imaging Conference Record,Dresden,Germany,2008:4662-4666.
  • 9Schlyer D,Vaska P,Tomasi D,et al.A simultaneous PET/MRI scanner based on RatCAP in small animals.IEEE Nuclear Science Symposium Medical Imaging Conference Record,Honolulu,2007:3256-3259.
  • 10Philips developing investigational PET/MR system.Field Strength,2010,41:37-38.

同被引文献43

  • 1胡峻.PET/CT图像融合技术及其临床应用[J].医疗装备,2005,18(3):26-27. 被引量:8
  • 2王亚丽.PET核医学成像原理分析[J].科技情报开发与经济,2007,17(18):162-163. 被引量:11
  • 3徐跃,梁碧玲.医学影像设备学[M].3版.北京:人民卫生出版社,2010.
  • 4Pichler BJ,Wehrl HF,Judenhofer MS.Latest advances in molecular imaging instrumentation[]] .J Nucl Med,2008,49(Suppl 2):S5-S23.
  • 5Schlemmer HP,Pichler BJ,Schmand M,et al.Simultaneous MR/ PET imaging of the human brain:feasibility study[J].Radiology, 2008,248 (3): 1028 - 1035.
  • 6Jadvar H,Colletti PM.Competitive advantage of PET/MRI[J]. EurJ P.adiol,2014,83(1) :84-94.
  • 7Judenhofer MS,Wehrl HF,Newport DF,et al.Simultaneous PET-MRI:a new approach for functional and morphological imaging[J].Nat Med,2008,14(4) :459-465.
  • 8Moehrs S,Del Guerra A,Herbert DJ,et al.A detector head design for small-animal PET with silicon photomultipliers (SiPM)[J]. Phys Med Biol,2006,51(5):1113-1127.
  • 9Boss A,Bisdas S,Kolb A,et al.Hybrid PET/MRI of intracranial masses:initial experiences and comparison to PET/CT[J].J Nucl Med,2010,51(8):1198-1205.
  • 10Martinez-Moller A,Nekolla SG.Attenuation correction for PET/MR:problems, novel approaches and practical solutions[J]. Z Med Phys,2012,22(4):299-310.