期刊文献+

国内FGD装置中鳞片衬里防腐蚀失效原因探讨

The discussion & analysis of anti-corrosion default in FGD with glass flaked vinyl ester liner
下载PDF
导出
摘要 湿法烟气脱硫装置因其处理烟气量大、脱硫率高、运行周期长、运营成本适中,已成为国内外火电厂烟气脱硫的主导装置。但该装置腐蚀环境苛刻,防腐蚀是FGD装置中的一个重要环节,而作为一种普通采用的鳞片衬裹材料,在国内的一些应用案例,出现了防腐蚀失效以至失败的情况,本文就FGD装置的失效情况进行分析和总结,找出原因以及对策,为后绩烟气脱硫装置的防腐蚀技术提供可靠的技术借鉴。 FGD is now the most common desulfric equipment in China now on the basis of its benefit and glass flaked vinyl ester is most employed as anti-corrosion lining thereby. However in this rapid booming market, some cases concerning the default lining were also ongoing. In this paper, we discuss and analyze these default cases for some conclusion, which in return are of assistance to the sustained anti-corrosion lining in these FGD.
出处 《Journal of Environmental Science and Engineering》 2008年第12期6-10,共5页 环境科学与工程(英文版)
关键词 鳞片衬表 FGD脱硫装置 防腐蚀 失效分析 讨论 VEGF lining FGD anti-corrosion default failure analysis discussion
  • 相关文献

参考文献5

  • 1王天堂,陆士平.VEGF鳞片胶泥在烟气脱硫装置中的应用[J].中国环保产业,2002(2):70-72. 被引量:17
  • 2胡建民.中国火电厂二氧化硫排放与控制的现状及展望.中国环境科学学会编.第七届全国大气环境学术会议论文集.中国环境科学出版社,1999.
  • 3Mitsru Takeshita, Hermine Soud. FGD Performance & Experience on Coal-fired Plants. London: IEA Coal Research 58, 1993: 7.
  • 4蔡洪良.火电厂脱硫后烟气条什、烟囱选型和防腐措施简述[C]//以上电力土建科技创新推进可持续发展学术交流会.中国电力工程顾问集团华东电力设计院,2005年.
  • 5Smigelski Je and I. A. Maroti. Design and operation of a wet process based FGD system withour reheat. Tenth Symposium on FGD, Atlanta, Georgia, 1986, 11: 18-21.