摘要
保定站由于建筑结构和使用功能的特殊性对消防设计提出了新的挑战。介绍了新建保定站概况、消防防火分区及主要存在的消防问题,提出了适合于保定站房性能化防火初步设计方案,并给出了具体的消防安全策略。模拟结果表明这些消防措施基本合理,消防安全设计基本上可以满足消防安全要求,达到了性能化消防设计的目的。
The special building structure and functions of the Baoding station poses new challenges for fire protection design.This paper introduces the general situation,new Baoding station fire protection division,main existing problems of fire prevention,and preliminary performance-based fire-protection design with specific fire protection strategies put forward for Baoding station.Simulation results show that the fire control measures are basically reasonable,fire safety design can basically meet the fire safety requirements and performance-based fire protection design purposes are reached.
出处
《铁道建筑技术》
2011年第4期91-94,共4页
Railway Construction Technology
关键词
铁路车站
防火分区
消防性能化
设计方案
安全策略
railway station
fire protection division
performance-based fire protection
design scheme