期刊文献+

激光导管拔除心脏起搏除颤导线的临床应用研究 被引量:4

Pacemaker/ICD lead extraction with the excimer laser sheath: a single center experience
原文传递
导出
摘要 目的 研究旨在分析激光导管拔除心脏起搏除颤导线的安全性和有效性.方法回顾性分析美国明尼苏达大学退役军人医疗中心自2008年3月至2009年12月间用激光导管拔除起搏除颤导线的连续16例患者,通过对患者的一般临床状况、基础疾病、心功能状态、起搏除颤导线拔除原因、导线状况及并发症等进行分析,了解激光拔除起搏除颤导线的方法、步骤、安全性和有效性,并总结手术经验及减少并发症的方法.结果 16例患者均为男性,年龄54~82(67.4 ±9.1)岁,多数患者均有严重的心脏疾病,左室射血分数为20%~60%(36.4±13.4)%.16例中,9例为拔除导线的Ⅰ类适应证,7例患者为Ⅱ类适应证.导线置入的时间为3~251(73.9±62.9)个月,其中时间最长者达251个月.共拔除导线31根,其中25根使用激光导管.所有患者均成功拔除导线,没有并发症.其中1例患者心房导线被拉断,经股静脉送入抓取工具后将导线残段经股静脉拉出,没有并发症发生;另1例患者成功拔除了3根导线,但在升级BiV-埋藏式心脏自动复律除颤器手术时导致冠状窦夹层及心包积液,未进行心包穿刺而稳定出院.结论初步研究资料表明,应用激光导管等综合方法和工具经静脉拔除心脏起搏除颤导线是安全、有效的. Objective The aim of this study is to investigate the safety and effectiveness of Excimer laser-assisted lead extraction. Methods Consecutive lead extraction in 16 patients using the excimer laser sheath from Veterans Administration Medical Center, University of Minnesota between March 2008 and December 2009 were analyzed retrospectively. The clinical characteristics including basic disease, cardiac function, indication and reason for lead removal, lead characteristic, and complication were summarized. Results Thirty one leads ( laser sheaths were used in 25 leads) in 16 patients [mean age (67.4 ±9. 1 )years, range 54-82 years] were extracted. All leads were extracted successfully without complication.Most patients had severe heart diseases with left ventricular ejection fraction of 20% -60% (mean 36. 4% ±13.4% ). Mean implant time was (73.9 ±62. 9)months (range 3 -251 months). Nine patients had Class Ⅰ indications for lead extraction, 7 patients for Class Ⅱ indications. Atrial lead fractured in one patient during lead extraction, the remaining part of the lead was taken out from femoral vein by a snare-catheter apparatus. Another patient developed CS dissection and small pericardium perfusion during LV lead implantation (upgrade to BiV-ICD ) post successful lead extraction and patient discharged without complication. Conclusion Our single center experience suggests that Excimer Laser Sheath Lead Removal System is safe and effective in extracting pacemaker and ICD leads.
出处 《中华心血管病杂志》 CAS CSCD 北大核心 2011年第4期363-368,共6页 Chinese Journal of Cardiology
关键词 导管插入术 外周 心脏起搏 人工 Catheterization, peripheral Cardiac pacing, artificial
  • 相关文献

参考文献12

  • 1Hauser RG,Katsiyiannis WT,Gornick CC.Deaths and cardiovascular injuries due to deviceassisted implantable cardioverter-defibrillator and pacemaker lead extraction.Europace,2009,12:395-401.
  • 2Love CJ,Wilkoff BL,Byrd CL,et al.Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads:Indications,Facilities,Training.Pacing Clin Electrophysiol,2000,23:544-551.
  • 3Wilkoff BL,Love CJ,Byrd CL,et al.Transvenous lead extraction:Heart Rhythm Society Expert Consensus on Facilities,Training,Indications,and Patient Management.Heart Rhythm,2009,6:1085-1094.
  • 4Smith MC,Love CJ.Extraction of transvenous pacing and ICD leads.Pacing Clin Electrophysiol,2008,31:736-752.
  • 5Bongiorni MG,Soldati E,Zucchelli G,et al.Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches:high success rate and safety in more than 2000 leads.Eur Heart J,2008,29:2886-2893.
  • 6Fischer A,Love B,Hansalia R,et al.Transfemoral snaring and stabilization of pacemaker and defibrillator leads to maintain vascular access during lead extraction.Pacing Clin Electrophysiol,2009,32:336-339.
  • 7Byrd CL,Wilkoff BL,Love CJ,et al.Intravascular extraction of problematic or infected permanent pacemaker leads:1994-1996.U.S.Extraction Database,MED Institute.Pacing Clin Electrophysiol,1999,22:1348-1357.
  • 8Wilkoff BL,Byrd CL,Love C J,et al.Trends in intravascular lead extraction:analysis of data from 5339 procedures in 10 years.XIth World Symposium on Cardiac Pacing and Electrophysiology:Berlin,Pacing Clin Electrophysiol,1999,22:6 pt Ⅱ,A207.
  • 9Kennergren C,Bucknall CA,Butter C,et al.Laser assisted lead extraction:the European experience.Europace,2007,9:651-656.
  • 10Kennergren C,Bjurman C,Wiklund R,et al.A single-centre experience of over one thousand lead extractions.Europace,2009,11:612-617.

同被引文献21

  • 1Arias MA, Puchol A, Castellanos E, et al. Ventricular oversensing after replacement of an implantable cardioverte~defibrillator. Pacing Clin Eleetrophysiol, 2009, 32: 925-927.
  • 2Makanee B, Gollob MH, Klein GJ, et al. Ten year follow-up of cardiac sympathectomy in a young woman with cateeholaminergic polymorphic ventricular tachycardia and an implantable cardioverter defibrillator. J Cardiovasc Electrophysiol, 2009, 20: 1167-1169.
  • 3Ozahowski TP, Greenberg ML, Mock P, et al. Implantable cardioverter defibrillator clinic casualties: inadvertent reprogramming during routine implantable cardioverter defibrillator follow-up. Pacing Clin Electrophysiol, 1996, 19.. 1524-1525.
  • 4Irie T, Kaneko Y, Nakajima T, et al. Unintentional protrusion and trapping of the screw-in helix of an implantable cardioverter Cardiovasc Electrophysiol, defibrillator lead. J 2011, 22.. 351.
  • 5Mond HG, Proclemer A. The 1 lth world survey of cardiac pacing and implantable cardioverter-defibrillators : calendar year 2009 - a World Society of Arrhythmia' s project [ J ]. Pacing Clin Electrophysiol, 2011, 34 ( 8 ) : 1013-1027.
  • 6李剑明,李延辉.激光鞘电极导线拔除术[M]//郭继鸿,胡大一.中国心律学2013.北京:人民卫生出版社,2013:317-331.
  • 7Candinas R, Duru F, Schneider J, et al. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads [ J ]. Mayo Clin Proc, 1999, 74 ( 2 ) : 120-125.
  • 8KozIowski D, Dubaniewicz A, Ko/luk E, et al. The morphological conditions of the permanent pacemaker lead extraction[J]. Folia Morphol (Warsz) , 2000, 59( 1 ) :25-29.
  • 9Novak M, Dvorak P, Kamaryt P, et al. Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes [ J]. Europace, 2009, 11 ( 11 ) : 1510-1516.
  • 10Koxodzifiska A, Kutarski A, Koperski L, et al. Differences in encapsulating lead tissue in patients who underwent transvenous lead removal[J]. Europace, 2012, 14(7):994-1001.

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部