期刊文献+

Analysis and Application of Variable Conductance Heat Pipe Air Preheater 被引量:1

Analysis and Application of Variable Conductance Heat Pipe Air Preheater
原文传递
导出
摘要 The heat transfer analysis of variable conductance heat pipe air preheater was carried out. The temperature trans-fer matrix was obtained for the air preheater that comprises several discrete heat transfer units with same or different heat transfer surface area in a parallel or counter flow mode. By using the temperature transfer matrix, the outlet fluid temperatures could be easily calculated for a given air preheater and inlet fluid temperatures. The active length of condenser in a variable conductance heat pipe is determined according to the flat interface model. With the same initial conditions, the comparisons between variable conductance heat-pipe air preheater and regular heat pipe air preheater has been analyzed and tested in terms of heat pipe wall temperature, heat transfer surface area and outlet fluid temperatures. Based on the real industrial applications, it has been confirmed that the variable conductance heat pipe air preheater has excellent performance of anti-corrosion and anti-ash-deposition especially at the variable working condition and the sulfur coal (5%-6% mass fraction of sulfur) condition. The heat transfer analysis of variable conductance heat pipe air preheater was carried out. The temperature trans-fer matrix was obtained for the air preheater that comprises several discrete heat transfer units with same or different heat transfer surface area in a parallel or counter flow mode. By using the temperature transfer matrix, the outlet fluid temperatures could be easily calculated for a given air preheater and inlet fluid temperatures. The active length of condenser in a variable conductance heat pipe is determined according to the flat interface model. With the same initial conditions, the comparisons between variable conductance heat-pipe air preheater and regular heat pipe air preheater has been analyzed and tested in terms of heat pipe wall temperature, heat transfer surface area and outlet fluid temperatures. Based on the real industrial applications, it has been confirmed that the variable conductance heat pipe air preheater has excellent performance of anti-corrosion and anti-ash-deposition especially at the variable working condition and the sulfur coal (5%-6% mass fraction of sulfur) condition.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2011年第3期248-253,共6页 热科学学报(英文版)
关键词 热管空气预热器 工业应用 电导 可变 流体温度 传热分析 转移矩阵 接口模型 variable conductance, heat pipe, air preheater, anti-corrosion, anti-ash deposition
  • 相关文献

参考文献1

二级参考文献4

  • 1住房和城乡建设部工程质量监管司.中国建筑标准设计研究院.全国民用建筑工程设计技术措施——电气[M].北京:中国计划出版社.2009.
  • 2石程名.低温自动保护热管空气预热器的传热性能[A]..第8届全国热管会议论文集[C].成都,2002(7)..
  • 3邓恩PP 雷伊PA.热管[M].北京:国防工业出版社,1982..
  • 4马钦 陈远国 袁毅.充气热管的传热性能试验[A]..第4届全国热管会议文集[C].牡丹江,1994..

共引文献3

同被引文献8

引证文献1

二级引证文献4