期刊文献+

Simultaneous determination of captopril and hydrochlorothiazide by time-resolved chemiluminescence with artificial neural network calibration 被引量:5

Simultaneous determination of captopril and hydrochlorothiazide by time-resolved chemiluminescence with artificial neural network calibration
下载PDF
导出
摘要 The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CPL)and hydrochlorothiazide(HCT).The stopped-flow technique in a continuous-flow system was employed in this work in order to emphasize the kinetic differences between the two analytes in cerium(IV)-rhodamine 6G CL system.After the flow was stopped,an initial rise of CL signal was observed for HCT standards,while a direct decay of CL signal was obtained for CPL standards.The mixed CL signal was monitored and recorded on the whole process of continuous-flow/stopped-flow,and the obtained data were processed by the chemometric approach of artificial neural network.The relative prediction error(RPE)of CPL and HCT was 5.9% and 8.7%,respectively.The recoveries of CPL and HCT in tablets were found to fall in the range between 95% and 106%.The proposed method was successfully applied to the simultaneous determination of CPL and HCT in a compound pharmaceutical formulation. The combined use of chemometrics and chemiluminescence(CL)measurements,with the aid of the stopped-flow mixing technique,developed a simple time-resolved CL method for the simultaneous determination of captopril(CPL)and hydrochlorothiazide(HCT).The stopped-flow technique in a continuous-flow system was employed in this work in order to emphasize the kinetic differences between the two analytes in cerium(IV)-rhodamine 6G CL system.After the flow was stopped,an initial rise of CL signal was observed for HCT standards,while a direct decay of CL signal was obtained for CPL standards.The mixed CL signal was monitored and recorded on the whole process of continuous-flow/stopped-flow,and the obtained data were processed by the chemometric approach of artificial neural network.The relative prediction error(RPE)of CPL and HCT was 5.9% and 8.7%,respectively.The recoveries of CPL and HCT in tablets were found to fall in the range between 95% and 106%.The proposed method was successfully applied to the simultaneous determination of CPL and HCT in a compound pharmaceutical formulation.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期32-38,共7页 药物分析学报(英文版)
基金 supported by the National Natural Science Foundation of China(No.20675063)
关键词 time-resolved chemiluminescence artificial neural network CAPTOPRIL HYDROCHLOROTHIAZIDE time-resolved chemiluminescence artificial neural network captopril hydrochlorothiazide
  • 相关文献

参考文献30

  • 1Yan Qing Chen Yong Nian Ni.Simultaneous spectrophotometric determination of four preservatives in foodstuffs by multivariate calibration and artificial neural networks[J].Chinese Chemical Letters,2009,20(5):615-619. 被引量:1
  • 2Baoxin Li,Yuezhen He,Jiagen Lv,Zhujun Zhang.Simultaneous determination of rifampicin and isoniazid by continuous-flow chemiluminescence with artificial neural network calibration[J]. Analytical and Bioanalytical Chemistry . 2005 (5)
  • 3Murillo Pulgarín JA,García Bermejo LF,Rubio Aranda JA.Time-resolved chemiluminescence:a novel tool for improved emission sequence instopped-flowanalysis:Applicationto a kinetic study of the oxidation of naloxone. Analytica Chimica Acta . 2004
  • 4Murillo PulgarínJA,García Bermejo LF,Fernández Lpez Pablo.Sensi-tive determination of captopril by time-resolved chemiluminescence using the stopped-flow analysis based on potassium permanganate oxidation. Analytica Chimica Acta . 2005
  • 5Murillo PulgarínJA,García Bermejo LF,Lemus GallegoJ M,et al.Sim-ultaneous stopped-flowdetermination of morphine and naloxone by time-resolved chemiluminescence. Talanta . 2008
  • 6Tom°u D,CataláIcardo M,Martínez CalatayudJ.Automatedsimultane-ous triple dissolution profiles of two drugs,sulphamethoxazole-trime-thoprimand hydrochlorothiazide-captopril insolid oral dosage forms by a multicommutation flow-assembly and derivative spectrophotometry. Journal of Pharmaceutical and Biomedical Analysis . 2004
  • 7Panderi I,Parissi-Poulou M.Determination of captopril and captopril-hydrochlorothiazide combinationintablets by derivative UVspectropho-tometry. International Journal of Pharmaceutics . 1992
  • 8Zhang ZD,Baeyens WRG,Zhang XR,et al.Chemiluminescence flow-injection analysis of captopril applying asensitizedrhodamine6G method. Journal of Pharmaceutical and Biomedical Analysis . 1996
  • 9Ribeiro MPA,Pádua TF,Leite OD,et al.Multivariatecalibration meth-ods applied to the monitoring of the enzymatic synthesis of amipicilin. ChemomIntell Lab Syst . 2008
  • 10Li BX,Wang DM,LüJG,et al.Chemometrics-assisted simultaneous determinationof cobalt (II)andchromium (III)withflow-injectionchemi-luminescence method. SpectrochimActa A . 2006

二级参考文献10

  • 1Association of Official Analytical Chemists International (AOAC),16th ed.,Official Methods of Analysis of AOAC International,vol.2,AOAC Inc.,Arlington,Virginia,1995.
  • 2V.A.Lozano,J.M.Cantina,M.S.Boefis,E.J.Marchevsky,Talanta 73 (2007) 282.
  • 3Z.Pan,L.L.Wang,W,M.Mo,C.Wang,W.Hu,J.J.Zhang,Anal.China.Acta 545 (2005) 218.
  • 4C.Z.Dong,Y.Mei,L.Chen,J.Chromatogr.A 1117 (2006) 109.
  • 5I.M.P.L.V.O.Ferreira,E.Mendes,P.Brito,M.A.Ferreira,Food Res.Int.33 (2000) 113.
  • 6I.Techakriengkrai,R.Surakarnkul,J.Food Comp.Anal.20 (2007) 220.
  • 7Q.C.Chen,J.Wang,J.Chromatogr.A 937 (2001) 57.
  • 8I.Pant,V.C.Trenerry,Food Chem.53 (1995) 219.
  • 9R.Driouich,T.Takayanagi,M.Oshima,S.Motomizu,J.Chromatogr.A 903 (2000) 271.
  • 10Y.N.Ni,G.W.Zhang,S.Kokot,Food Chem.89 (2005) 163.

同被引文献15

引证文献5

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部